Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HENNING Manuals
Measuring Instruments
MultiRope Series
Operating manual
HENNING MultiRope Series Operating Manual
Weight watcher light
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
page
of
16
Go
/
16
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Connection Diagram
Alarm Relays
HOLD-Function
How to Access a Parameter
How to Adjust a Parameter
Scheme of Menu
How to Calibrate the Load Measuring
Alarm Limits
How to Adjust the Display
Canopen Parameters (Optionally)
Electric Characteristics
Installation des Multirope
Operation Instructions in Brief
Advertisement
Quick Links
1
Connection Diagram
Download this manual
MULTIROPE
Operating Manual
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the MultiRope Series and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for HENNING MultiRope Series
Measuring Instruments HENNING MSM 12 Operating Instructions Manual
Mobile rope load meter (24 pages)
Measuring Instruments HENNING MSM12 V3 Manual
Mobile rope load measurement for sensors lsm 1, lsm 2 , lsm xl, lsm 2000, lsm belt (41 pages)
Measuring Instruments HENNING WeightWatcher Beam Operating Manual
(14 pages)
Measuring Instruments HENNING AE16 Light Operating Manual
Evaluation unit and rope load sensor (16 pages)
Measuring Instruments HENNING LS-Light Operating Manual
Evaluation unit and rope load sensor (16 pages)
Summary of Contents for HENNING MultiRope Series
Page 1
MULTIROPE Operating Manual...
Page 2
© Copyright 2016 by Henning GmbH & Co KG, Loher Str. 4, 58332 Schwelm Warranty This manual has been drawn up by Henning GmbH & Co. KG to the best of their knowledge. All technical statements have been carefully established an checked. They correspond to the state of the art.
Page 3: Table Of Contents
8. Alarm Limits........................ 10-11 9. How to Adjust the Display ....................11 10.a. CANopen Parameters (optionally) ................12 10.b. Electric Characteristics ....................13 11. Installation des Multirope ....................14 12. Operation Instructions in Brief ..................15 © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 4: Connection Diagram
NO contact Yellow NC contact Grey COM contact Pink NO contact Black NC contact Violet COM contact Grey/Pink GY/PK NO contact Red/Blau RD/BU NC contact White/Green WH/GN COM contact © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 5
Color/Colour Abbreviation Description White Supply voltage 24 V DC Brown Ground Pink + Hold input Blue - Hold input Green Can H Yellow CAN L Grey CAN Gnd © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 6: Alarm Relays
After ten minutes without any push of a button it changes into the energy-saving mode, i.e. the display goes off for being reactivated by the next push of a button. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 7: How To Adjust A Parameter
4.) After setting the last digit, press button again. After that the whole figure will be flashing. 5.) Press button once more to apply the adjusted parameter. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 8: Scheme Of Menu
(4 digits in the menu-item selected) calibrating of Multirope (cali) zero point adjustment (tara) state-changing thresholds of alarm-relays (alar) weight unit (unit) version number (Program-Version) CANopen (CANopen) © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 9: How To Calibrate The Load Measuring
) if you are going to load ¾ of the nominal load only. As soon as you will have adjusted the last digit, the whole figure will be flashing. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 10: Alarm Limits
Changes its state, if the load of one of the supporting means differs by the limit adjusted in paramete from the average load of all ropes. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 11: How To Adjust The Display
Empty cabin equals 0% (Load) Weights are displayed in tons. The function sets the gross weight to zero; after that, only the net weight of the cabin shown. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 12: Canopen Parameters (Optionally)
At this point, the event time in milliseconds, i.e. the time interval at which the load is written to the CAN bus, can be set. A value of 0000 overrides this function. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 13: Electric Characteristics
125 V AC 0,3 A max. switching capacity 62 VA (resistive load) max. switching capacity 62 VA (inductive load) min. switching load DC 10 mV DC 0,01 mA Galvanically isolated © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 14: Installation Des Multirope
Introduce the clamping brace over the 4 aligned bolts of the heel. Alternately tighten up the 4 nuts until the rope sits close against the heel of the clamping brace. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 15: Operation Instructions In Brief
Press times to confirm the adjustment. 5.) Connect the control lines to the lift controller and make sure that you accordingly choose the make- resp. break-contact. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Page 16
© Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the MultiRope Series and is the answer not in the manual?
Questions and answers