  • Page 1 MULTIROPE Operating Manual...
  • Page 2 © Copyright 2016 by Henning GmbH & Co KG, Loher Str. 4, 58332 Schwelm Warranty This manual has been drawn up by Henning GmbH & Co. KG to the best of their knowledge. All technical statements have been carefully established an checked. They correspond to the state of the art.
  • Page 3: Table Of Contents

    8. Alarm Limits........................ 10-11 9. How to Adjust the Display ....................11 10.a. CANopen Parameters (optionally) ................12 10.b. Electric Characteristics ....................13 11. Installation des Multirope ....................14 12. Operation Instructions in Brief ..................15 © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 4: Connection Diagram

    NO contact Yellow NC contact Grey COM contact Pink NO contact Black NC contact Violet COM contact Grey/Pink GY/PK NO contact Red/Blau RD/BU NC contact White/Green WH/GN COM contact © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 5 Color/Colour Abbreviation Description White Supply voltage 24 V DC Brown Ground Pink + Hold input Blue - Hold input Green Can H Yellow CAN L Grey CAN Gnd © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 6: Alarm Relays

    After ten minutes without any push of a button it changes into the energy-saving mode, i.e. the display goes off for being reactivated by the next push of a button. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 7: How To Adjust A Parameter

    4.) After setting the last digit, press button again. After that the whole figure will be flashing. 5.) Press button once more to apply the adjusted parameter. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 8: Scheme Of Menu

    (4 digits in the menu-item selected)  calibrating of Multirope (cali)  zero point adjustment (tara)  state-changing thresholds of alarm-relays (alar)  weight unit (unit)  version number (Program-Version)  CANopen (CANopen) © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 9: How To Calibrate The Load Measuring

    ) if you are going to load ¾ of the nominal load only. As soon as you will have adjusted the last digit, the whole figure will be flashing. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 10: Alarm Limits

    Changes its state, if the load of one of the supporting means differs by the limit  adjusted in paramete from the average load of all ropes. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 11: How To Adjust The Display

    Empty cabin equals 0%  (Load) Weights are displayed in tons.   The function sets the gross weight to zero; after that, only the net weight of the cabin shown. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 12: Canopen Parameters (Optionally)

    At this point, the event time in milliseconds, i.e. the time interval at which the load is written to the CAN bus, can be set. A value of 0000 overrides this function. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 13: Electric Characteristics

    125 V AC 0,3 A max. switching capacity 62 VA (resistive load) max. switching capacity 62 VA (inductive load) min. switching load DC 10 mV DC 0,01 mA Galvanically isolated © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 14: Installation Des Multirope

    Introduce the clamping brace over the 4 aligned bolts of the heel. Alternately tighten up the 4 nuts until the rope sits close against the heel of the clamping brace. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 15: Operation Instructions In Brief

    Press times to confirm the adjustment. 5.) Connect the control lines to the lift controller and make sure that you accordingly choose the make- resp. break-contact. © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...
  • Page 16 © Copyright 2016 by Henning GmbH & Co. KG Rev. 2.1 09/2016...