Honeywell F58G Series Product Data

Honeywell F58G Series Product Data

Commercial duct mounted electronic air cleaner
Hide thumbs Also See for F58G Series:

Advertisement

F58G,H and F58GUV Series
Commercial Duct Mounted
Electronic Air Cleaner

APPLICATION

The high-efficiency F58G,H Commercial Electronic Air
Cleaner is mounted to the return air duct of a forced-air
heating, cooling, or ventilating system. It captures a
significant amount of airborne particles 0.3 micron and
larger from the air circulated through it. F58H requires
connection to F58G power supply.
WARNING
Ultraviolet Radiation Hazard.
Read Operator's Manual.
Original Manual

FEATURES

• Capacity to 2000 cfm (3400 m
3
1000 cfm (1700 m
/hr) per F58H unit.
• Multiple units may be interconnected to form an
array of air cleaners.
• Solid-state power supply is self-regulating and
maintains peak efficiency during a wide range of cell
dirt-loading conditions.
• Indicator lights signal proper operation and fault
conditions.
• May be connected to a building management system.
• Relay closure occurs when fault occurs or when cells
need cleaning
• Galvanized cabinet protects against rust.
• Test button checks system operation.
• Pre-filter screen protects cells from large dirt
particles.
• F58G UV includes 55 W high irradiation UV lamp.
• UV lamp can be operated continuously during
equipment operation.
• UV-C can eliminate micro-organic contaminants that
adhere to the EAC cells.
Application .....................................................................................
Features ..........................................................................................
Specifications ...............................................................................
Ordering Information ................................................................
Planning the Installation .........................................................
Installation ....................................................................................
Wiring ..............................................................................................
Operation .......................................................................................
Checkout ........................................................................................
Service .............................................................................................
Electrical Troubleshooting ...................................................... 12
Parts List ........................................................................................ 14
PRODUCT DATA
3
/hr) per F58G unit,
Contents
1
1
2
2
5
6
7
9
9
9
31-00442-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F58G Series

  • Page 1: Table Of Contents

    F58G,H and F58GUV Series Commercial Duct Mounted Electronic Air Cleaner PRODUCT DATA FEATURES • Capacity to 2000 cfm (3400 m /hr) per F58G unit, 1000 cfm (1700 m /hr) per F58H unit. • Multiple units may be interconnected to form an array of air cleaners.
  • Page 2: Specifications

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER SPECIFICATIONS Accessories: 202614 Carbon Filter. 13643AA Ionizer Wires (quantity 5). IMPORTANT 32350736-001 UV tube. The specifications given in this publication do not Repair Parts: See Parts List section. include normal manufacturing tolerances. There- fore, this unit may not exactly match the listed Regulatory Approvals: specifications.
  • Page 3 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER PARTICAL DIAMETER ( m) EFFICIENCY RATINGS BASED ON AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS STANDARDS 52.2-2012 Fig. 1. F58G air cleaner efficiency at 1708 cfm, 492 fpm. (124.4) (99.5) (74.7)
  • Page 4 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER Fig. 3. F58G Installation dimensions of electronic air cleaner in in. (mm). Shown with UV lamp (optional). (610) 6-3/4 13-25/32 (171) (350) 3/8(10) Fig. 4. F58H Installation dimensions of electronic air cleaner in in. (mm). 31-00442—01...
  • Page 5: Planning The Installation

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER PLANNING THE Choosing Mounting Position INSTALLATION WARNING Notice: Heavy Equipment Hazard. Can cause injury or equipment damage. • Read the maintenance instructions before opening the Mount the air cleaner with the power supply on top. appliance.
  • Page 6: Installation

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER CROSS SUPPORTS AIR HANDLER 20 DEGREE ANGLE PER ATTACHED TO DUCT FLANGE DUCT FLANGE SIDE PER FITTING, 4 in. PER LINEAR FOOT (1M PER 3 LINEAR METERS). AIR HANDLER DUCT AIR HANDLER DUCT AIR FLOW M13457...
  • Page 7: Wiring

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER Fastening Cabinet to Air Handler WIRING Duct Flange  Remove and set aside the pre-filter and electronic cells. WARNING  Assemble the array of air cleaner units in the required Electric Shock Hazard.
  • Page 8 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER BLACK BLACK TEST BUTTON BOARD POWER JUNCTION BOX SUPPLY P.S. EFFY BOARD ELECTRONIC CELL BLACK BROWN GREEN GREEN YELLOW YELLOW GREEN YELLOW ON/OFF SWITCH. INTERLOCK SWITCH (SWITCH OFF WHEN REMOVING PRE-FILTER AND SWITCH ON WHEN PRE-FILTER INSTALLED).
  • Page 9: Operation

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER OPERATION SERVICE Large particles (lint and hair) are caught in the pre-filter. As the dirty air passes through the intense high-voltage CAUTION electric field surrounding the ionizer wires, all particles are Sharp Edges.
  • Page 10 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER 2. Using regular dishwashing detergent, allow the dish- 4. Wash the pre-filters following step 3. Empty and rinse washer to run through the complete wash and rinse the wash container. cycle.
  • Page 11 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER Replacement of UVC tube REPLACING AN IONIZER WIRE. WARNING Breakable Glass Hazard. Can cause personal injury. Be careful when inserting bulb into lamp base. Wear protective gloves when handling the bulbs. Be careful when inserting bulb into lamp base, wear protective gloves, long sleeve clothes and face shield to avoid skin exposed to the UV when...
  • Page 12: Electrical Troubleshooting

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER 1. Install 202614 Carbon Filters (sold separately). ELECTRICAL a. Turn the air cleaner power switch to the OFF posi- TROUBLESHOOTING tion. b. Remove the pre-filter and two electronic cells. c. Install carbon filters in the rear of the air cleaner cabinet.
  • Page 13 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER START TO USE THIS CHART: FOLLOW THE STEPS IN ORDER; DO NOT SKIP AROUND. EACH TIME YOU ISOLATE AND FIX A PROBLEM, GO BACK TO START. MAKE SURE ELECTRONIC REPEAT ALL THE STEPS UNTIL THE AIR CLEANER CHECKS OUT OK. CELLS ARE CLEAN, DRY AND PROPERLY INSTALLED.
  • Page 14: Parts List

    F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER PARTS LIST Table 3. F58G Parts List. Reference No. Description Part Number Electronic Cell FC37B1030/U Cell Handle Y016 Prefilter Assembly 50081476-001 Power Supply, 100~240 V a.c., 50/60 Hz 42009287AP Power supply, 220/240 V a.c., 50 Hz, CE version 42009287APE Interlock Switch 196277...
  • Page 15 F58G,H AND F58GUV SERIES COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER Table 4. F58H Parts List. Reference No. Description Part Number Prefilter 50081476-002 Electronic Cell FC37B1030/U Contact Board Assembly 32003893-001 Interlock Switch 196227 Optional Accessories (not shown in diagram) Ionizer Wires (Quantity 5) 136434AA Carbon Filter (Only applicable for NON-UV version) 202614...
  • Page 16 32000388-481 32000392-551 32000392-689 32000387-412 32000393-024 32002633-004 Manufacture: Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd Address: 158 Nan Hai Road, TEDA, Tianjin, 300457 Honeywell Building Technologies Honeywell GmbH Böblinger Strasse 17 71101 Schönaich, Germany Phone +49 (0) 7031 637 01 ®...

This manual is also suitable for:

F58h seriesF58guv seriesF58g1016eF58h1006F58g1016euv

Table of Contents