The F59A Console Electronic Air Cleaner
cleans the air in enclosed spaces such as offices or
homes. A 3-speed fan draws room air through an
electronic cell and activated carbon filter to remove
dust, lint, pollen, tobacco smoke, cooking smoke
and household odors.
Furniture styled wood-grained cabinet.
Circulates and cleans approximately 4400 ft
[125m
3
] of air 4-1/2 times an hour. Typically this is
a 25 by 22 ft [8 by 7m] room. Two or more F59A units
may be used in larger rooms.
Up to 90 percent air cleaning efficiency as measured
according to the National Bureau of Standards Dust
Spot Method using atmospheric dust, and the Ameri-
can Society of Heating, Refrigerating, and Air-Con-
ditioning Engineers Standard 52-76.
Suitable for commercial or residential use.
Three-speed motor-driven fan circulates up to
3
330 cfm [560 m
/hr].
Interlock switches prevent operation when cover is
removed.
F59A Console 3-Speed
Electronic Air Cleaner
Neon light indicates electronic air cleaner operation.
3
Powered from standard grounded outlet.
Electronic cell is easily removed for cleaning.
Prefilter screens out large particles such as dust or
lint.
Activated carbon postfilter removes gaseous con-
taminants and odors.
Optional casters allow easy movement of electronic
air cleaner.
CONTENTS
Specifications ................................................ 2
Ordering Information .................................... 2
Setup and Operation ..................................... 3
Service ........................................................... 3
Electrical Troubleshooting ............................ 5
Parts List ..................................................... 10
J. H. • Rev. 2-95 • ©Honeywell Inc. 1995 • Form Number 68-0086-5
1
68-0086-5

Advertisement

loading

Summary of Contents for Honeywell F59A

  • Page 1: Table Of Contents

    Powered from standard grounded outlet. [125m ] of air 4-1/2 times an hour. Typically this is a 25 by 22 ft [8 by 7m] room. Two or more F59A units Electronic cell is easily removed for cleaning. may be used in larger rooms.
  • Page 2: Specifications

    If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Logistics Honeywell Inc., 1885 Douglas Drive North...
  • Page 3: Setup And Operation

    See Fig. 1. CELL PREFILTER SET UP ELECTRONIC AIR CLEANER Position the F59A so: • the airflow in and out of the air cleaner is not blocked or partially obstructed. • the discharge air does not cause uncomfortable drafts for any occupant.
  • Page 4 F59A SERVICE • Be careful to avoid damaging or bending the cell 5. Rinse the cell with a hard spray of very hot water; plates when placing the cell in the dishwasher. If rinse the tub clean, then fill the tub with clean hot water and bent, arcing will result.
  • Page 5: Electrical Troubleshooting

    F59A SERVICE • ELECTRICAL TROUBLESHOOTING Turn on the air cleaner. If the cell and filters are wet, the be used temporarily with one wire missing, although the neon light may not come on; you may also hear arcing. wire should be replaced as soon as possible. See the Parts If the arcing is annoying, simply turn off the air cleaner List, for order number.Replacement wires are supplied cut...
  • Page 6 See Parts List Always turn off power before troubleshooting. section, for order number. Fig. 6—Troubleshooting the F59A. TROUBLESHOOTING F59A ELECTRONIC AIR CLEANER START TO USE THIS CHART: MAKE SURE 1. Be sure to follow the steps sequentially.
  • Page 7 PUSH SCREWDRIVER DOWN TO CLOSE INTERLOCK SWITCH CELL FRAME COLLECTOR PLATES M5634 M5637 Fig. 8—Internal schematic for 120 Vac, 60 Hz F59A. POWER SU PPLY RED -IONIZER NEON BL ACK-COLL ECTOR LIGH T YELL OW N EON L AMP GR EEN...
  • Page 8 F59A ELECTRICAL TROUBLESHOOTING Fig. 9—Internal schematic for 220 Vac, 50 Hz F59A. POWER SU PPLY RED -IONIZER NEON BL ACK-COLL ECTOR LIGH T YELL OW N EON L AMP GR EEN GROUND ON-OFF/ BLAC K 3 SPEED ON (C OM)
  • Page 9 F59A ELECTRICAL TROUBLESHOOTING Fig. 10—Use an ohmmeter to check the cell for short circuits as instructed in Fig. 6. COLLECTOR TERMINAL IONIZER TERMINAL COLLECTOR TERMINAL M6155 Fig. 11—Clip out the J2 jumper to reduce ozone production about 20 to 25 percent.
  • Page 10: Parts List

    F59A PARTS LIST Parts List Part Number Number Description 120 Vac, 60 Hz 220 Vac, 50 Hz Prefilter 190356 190356 Electronic Cell FC37A1130 FC37A1130 Contact Panel 138889A 138889A Solid State Power Supply 203362J 203362W Neon Light 190340 190340 Fan Motor...
  • Page 11 F59A PARTS LIST Fig. 12—F59A parts are keyed to parts list. M3151 This equipment is a class B digital apparatus which complies with Canadian Radio Interference Regulations, CRC c. 1374. 68-0086—5...
  • Page 12 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario QUALITY IS KEY M1P 2V9 68-0086—5 Printed in U.S.A.