Optimus UMX-CC Operating Instructions Manual page 14

Audio ip management card for umx-02/0 modular matrix
Table of Contents

Advertisement

In both cases, a web page belonging to
the unit will load.
NB: To be able to view the page, it is
necessary to deactivate the proxy in the
configuration of the web page browser.
Proceed as follows:
1. Enter the password in the Administrator
Login section (2) (contact technical staff
at Optimus and they will provide you
with this) and click on Login (3).
2. Open the Expert menu (4) and click on
the Set IP address option (5).
ATTENTION
If you activate the IP by software, the
functionality of IP address selection by
DIP switches will be deactivated.
Once the change has been made, it can
be undone by deleting the IP software via
the web, or by selecting the address
0.0.0.0 on the DIP switches and restarting
the unit.
3. Write the new IP in the IP Address field
(6) (for example: 10.1.1.100) and click
on Save IP Address (7).
ATENCIÓN
Once the IP address of the unit has been
changed, it is necessary to modify this in
the P.A. Manager software as well (see
section 3.4) and to send configurations to
the UMX-CC card (see section 3.6).
UMX-CC version 1.0
UMX-CC
(2)
(3)
(4)
(5)
AUDIO IP MANAGEMENT CARD
FOR UMX-02/0 MODULAR MATRIX
(6)
(7)
R&D Department
14