ADD USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter the Manager combination and hold down last digit of combination until the lock
signals with two sets of double beeps.
2. Press 1. Lock signals twice.
3. Enter user combination twice. The lock signals twice after each valid entry.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Combination Entry - Double signal after valid six (6) digit combination is entered.
• Invalid Combination Entry - Triple signal indicates the old combination is still valid.
DISABLE USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter the Manager combination and hold down last digit of combination until the lock
signals with two sets of double beeps.
2. Press 2. Lock signals once.
3. User is temporarily disabled. (User combination is saved and will be valid if reinstated.)
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
REINSTATE USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter the Manager combination and hold down last digit of combination until the lock
signals with two sets of double beeps.
2. Press 1. Lock signals once.
3. User is reinstated.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
DELETE USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager combination and hold down last digit of combination until the lock
signals with two sets of double beeps.
2. Press 3. Lock signals once.
3. User and combination are removed from lock. (Add User feature is still available.)
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
WRONG TRY PENALTY
• Entry of four (4) consecutive invalid combinations starts a five (5) minute delay period.
- LED flashes red at ten (10) second intervals.
• At the end of the delay period, two more consecutive invalid combinations will restart
the five (5) minute delay period.

BATTERY LOW WARNING

• Repeated LED flashing and beeping during an opening indicates that the battery is low
and needs immediate replacement.
• Uses one (1) 9-Volt alkaline battery only. (Example: Duracell™ or Energizer™ alkaline
batteries.) It is recommended that batteries be replaced at least once annually.
• Lock contains a non-volatile memory; even with the batteries removed the lock
will retain all programming.
For battery replacement instructions, see input unit's "User Operation" Guide.
Mounting instructions available at www.kaba-mas.com.