Schako NOVENCO NovAx ACP Series Installation And Maintenance Manual

Advertisement

Quick Links

Pure competence in air.
ACP / ACG
INSTALLATION
AND MAINTENANCE
916331-0
ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NOVENCO NovAx ACP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Schako NOVENCO NovAx ACP Series

  • Page 1 Pure competence in air. ACP / ACG INSTALLATION AND MAINTENANCE 916331-0 ENGLISH...
  • Page 2 916331-0 NovAx™ axial flow fans types ACP and ACG Installation and maintenance 1. Application 2. Handling 2.2 Weight The total weights are determined on the 2.1 Marking 2. Handling basis of fan type and size as well as the The ACP and ACG fans are provided with Marking maximum motor size employed.
  • Page 3 Lifting and transport must be done with on the pressure side. The ACG is fitted with the casing. care, as the fans are vulnerable to a downstream guide vane arrangement. vibrations and shocks. These can result in 4.1 Prior to installation imbalance and deformations.
  • Page 4 fan, anti-vibration mountings may be It is important to allow for free areas to 5. Start of operation inserted between fan and support and facilitate mounting and dismounting as 5.1 Prior to start of operation flexible connections fitted in the ducts after well as ordinary maintenance.
  • Page 5 mm/s, rms*, is not allowed in case of motors. (in case of blade pitch increase). position on feet or anti-vibration 6.5 Dismounting of motor Contact Novenco before any such mountings. adjustment of the blade pitch. * ISO 2954, Requirements for instruments Prior to commencing the work, switch off for measuring vibration severity.
  • Page 6 Novenco Building & Industry A/S Industrivej 22 Tel. +45 70 77 88 99 4700 Naestved www.novenco-building.com Denmark 8. Trademarks and copyright Safety of machinery - Safety distances EN 60204-1 ® ® Novenco , ZerAx Safety of machinery - Electrical are registered trademarks of equipment of machines Part 1: Novenco A/S.
  • Page 7 Appendices – wiring diagrams A. Motors up to 16 A – delta Figure 8. Terminal box delta connected for motors below 16 A B. Motors up to 16 A – star Figure 9. Terminal box star connected for motors below 16 A C.
  • Page 8 Pure competence in air. WWW.NOVENCO-BUILDING.COM...