For the following instructions, refer to F
1. Press PRGM button once to enter programming
field.
2. Press SLCT button to move from CONFIGURA-
TION?ZONE1, to CONFIGURATION?ZONE2, to
SERIAL PORT, and to GLOBAL SETTINGS.
3. When the desired field is selected, pressing the
PRGM button scrolls through the options within that
field.
4. Pressing the SLCT button toggles through the
choices available for the selected option.
313903B
RST/CLR SLCT
RST/CLR SLCT
CONFIGURATION?
CONFIGURATION?
- ENABLE ZONE
- ENABLE ZONE
- UNITS OF MEASURE
- UNITS OF MEASURE
- PORT TOTAL
- PORT TOTAL
- FAULT SETUP
- FAULT SETUP
- FLOW ALARM ON
- FLOW ALARM ON
- LOW FLOW SET
- LOW FLOW SET
- HIGH FLOW SET
- HIGH FLOW SET
- ENABLE TACH
- ENABLE TACH
- SET # PULSES/REV
- SET # PULSES/REV
- SET NORMAL RPM
- SET NORMAL RPM
RST/CLR SLCT
RST/CLR SLCT
. 11.
IG
Programming the Lube Sentinel II Monitor
Press PRGM button to
enter programming field.
PRGM
PRGM
Press SLCT button to toggle between four fields.
Fields
SERIAL PORT
- BAUD RATE
- WORD LENGTH
- STOP BITS
- PARITY
Press PRGM button to scroll
through field options.
PRGM
PRGM
Press SLCT button to toggle through choices for
selected options.
Saving Program Changes
1. When the display shows CONFIGURA-
TION?ZONE1, CONFIGURATION?ZONE2,
SERIAL PORT, or GLOBAL SETTINGS, press the
RST/CLR button to place the Sentinel II in the moni-
tor mode.
2. A prompt will ask if any changes should be saved.
The default is NO. To save the changes, press the
SLCT button to change to YES.
3. Then press the PRGM button.
NOTE: Pressing any other button when NO is showing
will erase any changes indicated and leave all settings
as they were before entering the programming function.
GLOBAL SETTINGS
- FAULTS TO SKIP
(Nuisance Faults)
- INVERT RELAYS
(Fault Relay Logic)
13