Graco Matrix 312964C Manual

Tank level monitor (tlm) for oil and anti-freeze mixtures

Advertisement

Quick Links

Tank Level Monitor (TLM)
- Monitors tanks levels for oil and anti-freeze mixtures -
Part No. 256285
Use with Graco Matrix 3.0 Software only.
US Patent D484,819
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Not for use in hazardous locations or in explosive
atmospheres!
Do not over tighten tank level monitor into tank bung!
Over tightening can cause permanent damage and result
in inaccurate readings.
Do not use thread sealant or adhesive! Many of these
products are chemically incompatible with the PC/ABS
plastic.
Use the Graco-supplied down tube 15U731 only. Do not
replace down tube with any other tube.
The Matrix Tank Level Monitor contains an RF device with the following approvals:
FCC ID: TFB-FREESTAR
IC: 5969A-FREESTAR
Industry Canada Statement
The term "IC" before the certification/registra-
tion number only signifies that the Industry
Canada technical specifications were met.
NOTICE
N14939 - FREESTAR
ZFMSM-101-1 (CEL) / FS24-100ST (LSR)
312964C
EN
ti12031a

Advertisement

Table of Contents
loading

Summary of Contents for Graco Matrix 312964C

  • Page 1 PC/ABS plastic. • Use the Graco-supplied down tube 15U731 only. Do not replace down tube with any other tube. The Matrix Tank Level Monitor contains an RF device with the following approvals: FCC ID: TFB-FREESTAR ✓...
  • Page 2 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
  • Page 3: Dip Switch Settings

    Do not use thread sealant or adhesive. Many of these products are chemically incompatible with the PC/ABS plastic. • Use the Graco-supplied down tube 15U731 only. Do not replace down tube with any other tube. Dipswitch Settings 1. Remove the protective plastic over cover (5) on the The TLM has two, 4 - position dipswitches labeled S1 TLM display that was used for shipping and discard.
  • Page 4 Set Up 7. Install two, 9-volt alkaline batteries (1). Be sure that 9. Replace cover (7) and secure it with the four screws the batteries fully engage the mounting clips by (3). pushing on the bottom of each battery with your thumb.
  • Page 5 Set Up Dipswitch Setting for Network ID and Transceiver ID See F . 3 for dipswitch setting configurations. The batteries must be disconnected and removed before changing dipswitch settings or the TLM will not be able to communicate with the PC software. S2 Transceiver ID 1 - default S1 Network ID...
  • Page 6 Set Up Registering the TLM Graco recommends registering TLM prior to installa- See F . 4 for display messages you will see during tion. Registration Mode. The TLM operating parameters are controlled by the Matrix PC Software and setup by the System Adminis- trator.
  • Page 7 TLM Display TLM Display (See F . 6, page 8) Fluid Volume -Volume of fluid remaining in the tank, based on the tank geometry defined during setup. The TLM ID - Unique number assigned to the TLM to distin- TLM can be programmed to display in either gallons or guish it from other TLM’s in the system.
  • Page 8 TLM Registration Process TLM Registration Process Press & Hold DISPLAY button TLM ID Battery NW ID TX ID REGISTER MODE No Ack received from Ack received from Transceiver Transceiver TLM ID TLM ID Display Reads No RF Signal VERSION VERSION xx.xx.xx xx.xx.xx BLANK...
  • Page 9: Installation

    TLM will damage the unit and void the changed. warranty. Graco recommends that the height of the tank fitting Port (D) is not to be used as a fill hole for oil deliveries. should not exceed 1/2 in. (1.27 cm). The fitting See F .
  • Page 10: Viewing Data

    Viewing Data Viewing Data After a tank is refilled from an oil distributor or a waste oil tank is emptied by a waste oil service provider, press the Display button on the TLM to ensure the TLM will maintain the most current tank volume status.
  • Page 11: Troubleshooting

    Troubleshooting Troubleshooting Problem Cause Solution Brand new monitor’s dis- Unit is shipped with protective coat- Remove protective coating. play is very dim. ing over display. Monitor displays “Invalid The TLM reading is outside of the Verify the programmed parameters and re-program the TLM if Reading”.
  • Page 12 Troubleshooting Problem Cause Solution Monitor readings are Tank geometry incorrectly defined. See Tank Level Monitor Software Guide or PC Software Guide inaccurate. for details. Tank Level Monitor has not been Manually push DISPLAY button on TLM updated with latest adjustments made within The profile ID on the Two TLMs are programmed to the Verify that each TLM is correctly programmed to a unique...
  • Page 13: Replacing Batteries

    Service Service Once the Tank Level Monitor has been installed, no additional maintenance or service is necessary, with the excep- tion of replacing batteries. Replacing Batteries Always replace both batteries with two new 9-volt alkaline batteries whenever you change batteries in the TLM. Sparking can occur when changing batteries.
  • Page 14 Parts Parts ti12033a Remove protective cover used for shipping before programming. Do not remove. This is required to maintain intrinsic safety approval. Ref. Part No. Description BATTERY, 9 volt (purchased locally) 126752 GASKET, sensor, ultrasonic 117467 SCREW, self tapping, HI-LO, #10-16 x 9/16 117743 FOAM, insulator 117259 ENCLOSURE 15T814 LABEL, overlay...
  • Page 15: Technical Data

    15 in. (30.48 cm). TLM Mounting Tube and Tank Vent Graco recommends venting the tank separately from the TLM. If not possible, the TLM mounting and vent function can be combined if required for tanks with one hole in tank. Be sure TLM is not mounted close to tank edges or corner.
  • Page 16 Dimensions Dimensions 9.1 in (231 mm) 4.9 in. (124 mm) 1-1/2 in. npt 2 in. npt ti12031a 312964C...
  • Page 17: Tank Geometry

    Tank Geometry Tank Geometry Vertical Tank: • Maximum Volume = 999, 999 gallons or liters. • Tank walls must be uniformly vertical from empty level to full Maximum Height 30 ft. (360 in.) ti12693a . 10 312964C...
  • Page 18 Tank Geometry Cylindrical Tank: • Maximum Volume = 999, 999 gallons or liters. • Tank end walls must be flat; they cannot be any other shape, including belled. Maximum Height 30 ft. (360 in) Maximum Length 30 ft. (360 in) ti12695a .
  • Page 19 Tank Geometry Obround Tank: • Maximum Volume = 999, 999 gallons or liters. • Tank end walls must be flat; they cannot be any other shape including belled. Maximum Height 30 ft. (360 in) Maximum Width 30 ft. (360 in.) Maximum Length 30 ft.
  • Page 20 With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twenty four months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.