Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
21.6 Insert the flow rate regulator and secure with the locking ring.
a: Struts
b: Direction of flow
21.7 Reassemble in reverse order.

22. Replacing the non-return valve

Warning!
All non-return valves must be replaced at the same time.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
22.1 Remove the shower panel (see
22.2 Loosen the cap nuts (b).
22.3 Remove the hoses (a).
22.4 Remove the existing seals (c).
22.5 Remove the locking ring (d) on the inside using appropriate pliers for locking rings.
22.6 Pull the non-return valve (e) out of the function block using a special tool
(FAR-Best.-Nr. 2000105636).
22.7 Remove the lock (f) using an Allen key.
22.8 Remove the spacer (g).
22.9 Pull the non-return valve (h) out of the function block (i) using a special tool
(FAR-Best.-Nr. 2000105636).
Caution!
Note the installation position of the non-return valves.
22.10 Reassemble in reverse order.

23. Replace the functional element

23.1 Close the water volume regulator (see
23.2 Trigger the fitting.
23.3 Remove the cover platelet (a).
23.4 Remove the locking ring (b).
23.5 Remove the pressure cap (d) and the compression spring (c).
23.6 Unscrew the functional element using an Allen key (e; FAR-Best.Nr. 2000106127).
23.7 Reassemble in reverse order.
23.8 Check the flow time and adjust where necessary (see
Chapter
17.).
Work step
11.17).