COMTRAXX® COM463BC
Gateway for data exchange
between the interfaces BCOM and external BMS
Software version V4.0.x
Manual EN
COM463BC_D00427_00_M_XXEN/08.2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMTRAXX COM463BC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bender COMTRAXX COM463BC

  • Page 1 COMTRAXX® COM463BC Gateway for data exchange between the interfaces BCOM and external BMS Software version V4.0.x Manual EN COM463BC_D00427_00_M_XXEN/08.2020...
  • Page 2 Bender GmbH & Co. KG © Bender GmbH & Co. KG All rights reserved. PO Box 1161 • 35301 Grünberg • Germany Londorfer Straße 65 • 35305 Grünberg • Germany Reprinting only with permission Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 of the publisher.
  • Page 3: Table Of Contents

    Table of Contents 1. Important information ................... 5 How to use this manual ......................5 Technical support: service and support ................6 1.2.1 First level support ........................6 1.2.2 Repair service ..........................6 1.2.3 Field service ..........................7 Training courses ........................7 Delivery conditions .........................
  • Page 4 Table of Contents Display and control elements ................... 17 Commissioning the device ....................17 Factory settings for addresses ..................18 5. Web user interface ....................19 Functions of the web user interface ................19 Software products used ...................... 19 Browser configuration ......................19 Main page COMTRAXX®...
  • Page 5: Important Information

    COMTRAXX® is a registered trademark of Bender GmbH & Co. KG. Terms used This manual explains Bender-specific terms and functions in detail. Familiarisation with general spe- cialist IT and network terminology is considered a prerequisite. These terms are therefore only ex- plained briefly in this manual.
  • Page 6: Technical Support: Service And Support

    This manual has been compiled with great care. It may nevertheless contain errors and mistakes. Bender cannot accept any liability for injury to persons or damage to property resulting from errors or mistakes in this manual.
  • Page 7: Field Service

    **Mo-Thu 7.00 am - 8.00 pm, Fr 7.00 am - 13.00 pm 1.3 Training courses Bender is happy to provide training regarding the use of test equipment. The dates of training cours- es and workshops can be found on the Internet at www.bender.de > Know-how > Seminars.
  • Page 8: Warranty And Liability

     introduced to the market after 13th August 2005 must be taken back by the manufacturer and disposed of properly. For more information on the disposal of Bender devices, refer to our homepage at www.bender.de > Service & support. COM463BC_D00427_00_M_XXEN/08.2020...
  • Page 9: Safety Instructions

    2. Safety instructions 2.1 General safety instructions Part of the device documentation in addition to this manual are the enclosed "Safety instructions for Bender products". 2.2 Working on electrical installations Only qualified personnel are permitted to carry out the work necessary to mount, commission and run a device or system.
  • Page 10 Safety instructions COM463BC_D00427_00_M_XXEN/08.2020...
  • Page 11: Product Description

    The COM463BC gateways are integrated into the existing EDP structure like PCs. After connecting to the network and compatible Bender products, all system devices can be accessed from any PC using a standard web browser (e.g. Google Chrome, Mozilla Firefox, Internet Explorer). In this way, all im- portant system information is directly available.
  • Page 12: Functional Description

    3.6 BMS interface of the COM463BC External BMS bus (BMSe) Individual Bender devices, such as MK800, TM800 or Bender panels can communicate via the exter- nal BMS bus (BMSe). The COM463BC can communicate via the external BMS bus (BMSe). The COM463BC cannot param- eterise other bus devices on the external bus.
  • Page 13: Mounting, Connection And Commissioning

    For more detailed information on the topic of BMS, in particular about the wiring of bus devices, please refer to the separate document "BMS bus". You can obtain this document at: https://www.bender.de > Service & support > Downloads > Manuals 3. Does the computer network have a DHCP server? If the connected computer network contains a DHCP server, activate the "DHCP"...
  • Page 14: Mounting The Device

    Mounting, connection and commissioning Risk of fatal injury due to electric shock! Touching live parts of the system carries the risk of: An electric shock   DANGER Damage to the electrical installation   Destruction of the device   Before installing and connecting the device, make sure that the installation has been de-energised.
  • Page 15: Connecting The Device

    – Lights permanently as soon as the device is ready for operation. LEDs show activities on the different interfaces BMS bus (Bender measuring device interface): Terminals ABMS and BBMS Plug X1 Ethernet port (RJ45) for connection to the PC network as well as to BCOM...
  • Page 16: Wiring Diagram

    Mounting, connection and commissioning Make the connection as follows: 1. Remove terminal covers of the device 2. BMS bus connection: Connect the terminals ABMS and BBMS (4) to the BMS bus (A to A, B to B). If the COM463BC is at the end of the BMS bus, the terminating switch on the device (7) must be switched to "ON".
  • Page 17: Display And Control Elements

    Mounting, connection and commissioning 4.6 Display and control elements COM463BC COMTRAXX BCOM Fig. 4.3: Display and control elements COM463BC Item Function "ON" LED Flashes during start-up. The LED lights permanently as soon as the device is ready for operation. LEDs indicate activity on the various interfaces. 4.7 Commissioning the device 1.
  • Page 18: Factory Settings For Addresses

    Risk of duplicate addresses if BCOM system name is not changed. The factory setting for the system name on all Bender BCOM devices is "SYSTEM". If several systems are established in the same network, there is a risk that ad- dresses will be assigned more than once.
  • Page 19: Web User Interface

    5. Web user interface The web user interface of the device enables access via LAN, WLAN or the Internet. It provides a uni- form display of all connected Bender devices. 5.1 Functions of the web user interface Bus overview of the associated devices ...
  • Page 20: Main Page Comtraxx® User Interface

    Web user interface 5.4 Main page COMTRAXX® user interface 1. Open an Internet browser. 2. Enter the IP address of the gateway in the address line (example: http://172.16.60.72/). COM463BC Text ... COMTRAXX® 18.02.20 13:30 search System COM463BC (172.16.60.72) COM465_OP2 COM463BC 172.16.60.72 Subsystem 2 (172.16.60.28)
  • Page 21: Path Display (Breadcrumb Navigation)

    Web user interface 5.4.2 Path display (breadcrumb navigation) The path display shows at any time on which device and in which bus you are currently located in the content window. 5.4.3 Navigation Menu Description Display of information about the device and the software. Please have this Start information to hand if you need to contact us for assistance by telephone.
  • Page 22: Content Area

    Web user interface 5.4.5 Content area Display of the system, alarms and entries for the tools COM465IP Text ... COMTRAXX® 18.02.20 13:30 search COM465_OP2 COM465_OP2 Geräte Subsystem 2 Subsystem 30 (30) (50) Subsystem 50 Subsystem 2 Subsystem 30 Subsystem 50 Alarme 2 COM465IP Text ...
  • Page 23: Setting Up Password Protection For Com463Bcp

    Web user interface 5.4.7 Setting up password protection for COM463BCP Password protection can be configured for the roles User and Administrator. This allows regulating the access to the web user interface. Risk of damage to equipment due to unauthorised access The password protection for the gateway protects against unauthorised access to a limited extent only.
  • Page 24 Web user interface COM463BC_D00427_00_M_XXEN/08.2020...
  • Page 25: Troubleshooting

    COMTRAXX® manual). Frequently asked questions on the Internet FAQs on many Bender devices can be found at: https://www.bender.de > Service & support > Rapid assistance > FAQ 6.2 Maintenance The device does not contain any parts that require maintenance.
  • Page 26 Troubleshooting COM463BC_D00427_00_M_XXEN/08.2020...
  • Page 27: Technical Data

    7. Technical data 7.1 Tabular data Insulation coordination in acc. with IEC 60664-1/IEC 60664-3 Rated voltage................................ AC 250 V Rated impulse voltage/overvoltage category ......................4 kV/III Pollution degree ................................3 Protective separation (reinforced insulation) between ..................(A1/+, A2/-) - [(AMB, BMB), (ABMS, BBMS), (X2), (X3, X4)] Supply voltage Supply voltage .............................24…240 V...
  • Page 28: Standards, Approvals And Certifications

    Technical data Environment / EMC EMC ................................. EN 61326-1 Ambient temperatures Operating temperature ........................-25…+55 °C Transport ............................-40…+85 °C Long-term storage ..........................-25…+70 °C Classification of climatic conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) ..........3K24 (except condensation and formation of ice) Transport (IEC 60721-3-2) ..........................
  • Page 29: Index

    INDEX Address 18 Maintenance 25 Applications 11 Malfunctions 25 Approvals 28 Mounting and connection 13 BMS bus NTP server 13 - Address setting 9 - Termination 9 BMS interface 12 Ordering information 28 Browser - configuration 19 - Main page COMTRAXX 20 Qualified personnel 9 - User interface 19 Repair 6...
  • Page 30 INDEX COM463BC_D00427_00_M_XXEN/08.2020...
  • Page 32 Bender GmbH & Co. KG PO Box 1161 • 35301 Grünberg • Germany Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-mail: info@bender.de • www.bender.de BENDER Photos: Bender Archive...