General Information; Introduction; Warranty; Technical Assistance - Bradford White Copper Brute B4 Installation, Operation & Maintenance Instructions Manual

Volume water heaters
Hide thumbs Also See for Copper Brute B4:
Table of Contents

Advertisement

Internet Version for Reference Only
Copper Brute B4 Volume Water Heaters

SECTION 1.

General Information

1.1 Introduction

This manual provides installation, operating, and
maintenance instructions for Copper Brute Volume
Water Heaters, Sizes 175 through 400. Review all
application and installation procedures completely
before proceeding with the installation. Experience
has shown that most operating problems are caused by
improper installation.

1.2 Warranty

The Copper Brute heaters are sold with a limited
factory warranty.
Make all warranty claims to an authorized
Bradford White representative or directly to the
factory. Claims must include the heater serial number
and model (this information can be found on the rating
plate), installation date, and name of the installer.
Shipping costs are not included in the warranty
coverage.
Gas Connection
Nat.
Size
in.
175
/
3
4
250
/
3
4
325
/
3
4
400
/
3
4
Note: Dimensions may vary.
Figure 1. General configuration.
TOP VIEW
A
8-1/2 in.
(216mm)
INLET OUTLET
Dimensions shown in inches cm.
Size
Water
Connect.
Propane
Size
mm
in.
mm
in.
19
/
13
1
/
1
1
2
2
/
1
/
19
13
1
1
2
2
19
/
13
1
/
1
1
2
2
19
/
13
1
/
1
1
2
2
Some accessory items are shipped in separate
packages. Inspect everything for damage immediately
upon delivery, and advise the transporter of any
shortages or damage. Any such claims should be filed
with the transporter. The transporter will not accept a
claim from the shipper, Bradford White.
The warranty does not cover damage caused by
improper installation, operation, or field modification.

1.3 Technical Assistance

Consult Bradford White or your local wholesaler
with any questions or problems involving the
specification, installation and operation of Bradford
White equipment. An experienced technical support
staff is ready to assist in assuring the proper
performance and application of Bradford White
products.
SIDE VIEW
B
30-3/16 in. (767mm)
A
B
mm
in.
cm
in.
38
18
46
26
/
1
2
22
/
31
38
57
1
2
38
26
/
68
35
/
3
3
4
4
38
31
/
80
40
/
3
1
4
4
V
OPTIONAL
VENT CAP FOR
OUTDOOR USE
DRAFTHOOD MUST
C
BE INSTALLED IN
THE FIELD
OUTLET
INLET
5-1/2 in.
(140mm)
26-1/2 in.
(673mm)
C
C
U.S. Only
(Indoor)
(Outdoor)
cm
in.
cm
in.
67
14
/
36
23/
1
16
2
18
/
24
/
79
47
1
3
16
4
91
19
/
49
25
/
3
7
16
8
102
22
/
58
26
/
5
7
8
8
Page 3
DRAFTHOOD
C
HEADER
LOCATION
40-9/16 in. (1030mm)
V
Vent
Dia.
cm
in.
mm
60
6
152
7
63
178
66
8
203
68
9
229

Advertisement

Table of Contents
loading

Table of Contents

Save PDF