Bradford White 50T65F Service Manual page 6

Bradford-white corp flammable vapor ignition resistant water heater service manual
Hide thumbs Also See for 50T65F:
Table of Contents

Advertisement

Installation of Inner Door With Gasket.
Step 7.
Clean any residual gasket residue or other debris
from combustion chamber surface before
installing the inner door/gasket assembly.
Step 8.
Place the left side inner door into position first.
Firmly position the radiused channel of the inner
door around the feedline. Using the 1/4" hex drive
screws from step 3d, secure left side inner door in
place. DO NOT OVER TIGHTEN SCREWS.
Step 9
Position thermocouple, pilot tube and Piezo wire
against left side inner door flange gasket.
DO NOT ROUTE THROUGH RADIUSED
CHANNEL WITH FEEDLINE.
Radiused Channel
for Feedline
7
SERVICE PROCEDURE RG-I
Inner Door/Gasket Removal, Inspection
Replacement and Reinstallation
WARNING
Stripped fastener connections may allow
for seal breach of inner door. A seal
breach may result in a fire or explosion
causing property damage, personal injury
or death. Do not over tighten screws in
steps 8, 10 and 11.
If a fastener connection is stripped,
contact the manufacturer listed on the
water heater rating plate.
Position thermocouple,
pilot tube and piezo wire.

Advertisement

Table of Contents
loading

Table of Contents