Bradford White 50T65F Service Manual page 19

Bradford-white corp flammable vapor ignition resistant water heater service manual
Hide thumbs Also See for 50T65F:
Table of Contents

Advertisement

BURNER CLEANING (Cont.)
Step 5.
Disconnect (unscrew) Main burner (stamped steel "B" burner) from main
burner orifice or on cast iron burners ("C" burner), loosen air shutter &
disconnect (unscrew) feedline from burner.
Step 6.
Remove main burner orifice from feed line (½" wrench on steel
burner, 3/8" wrench on cast iron). Inspect and clean if necessary.
Step 7.
Remove pilot assembly, refer to SERVICE PROCEDURE RG-III for cleaning and inspection.
Step 8.
Reassemble burner.
Step 9.
Inspect combustion chamber area of heater prior to reinstallation of burner assembly. If cleaning is required,
refer to SERVICE PROCEDURE RG-VIII.
Step 10.
Reinstall burner assembly into combustion chamber, reconnect feedline, thermocouple and pilot tube to
the combination thermostat/gas valve.
Step 11.
Reinstall inner door per SERVICE PROCEDURE RG-I, steps 4 through 13.
Step 12.
To resume operation, follow the instructions located on the lighting instruction label or the lighting
instructions located in the installation and operation manual.
SERVICE PROCEDURE RG-VI
Burner Operation Inspection, Adjustment
Cleaning and Replacement
20

Advertisement

Table of Contents
loading

Table of Contents