Intended Use; Information On The Product; Model Code; Technical Data - Dimplex UPH 120-32 PK Installation And Operating Instruction

Circulating pump with automatic performance adjustment via pwm
Table of Contents

Advertisement

Available languages

Available languages

UPH 120-32PK
4

Intended use

This device must not be operated by persons (including chil-
dren) with limited physical, sensory or mental abilities or lacking
the necessary experience and/or knowledge.
Children must be supervised to ensure that they do not play
with the device.
The UPH 120-32 PK high efficiency pump is used for circulat-
ing liquids (not oils or oil-based liquids, not food) in:
Domestic hot water heating systems
Air conditioning, cooling and cold water circuits
Heat pumps, brine circuits
Closed industrial circulating systems
5

Information on the product

5.1 Model code

Example: UPH 120-32 PK
UPH
=
High efficiency pump
=
Electronically regulated
30
=
Screw connection
30 (G 2"AG)
1-12
=
adjustable controlling range of the
delivery height in (m)
PK
=
P = PWM input signal
K = constant controller or
p-c
p-v
Table 5.1:

5.2 Technical data

Max. discharge rate
Max. delivery height
Line voltage
Nominal current
Frequency
Insulation class
Degree of protection
Power consumption P1
Nominal widths
Connecting flange
Permissible
ambient temperature
Max. relative humidity
(pressure constant) and
(volume constant)
452115.66.46 · FD 0004
Approved media to be pumped are heating water in accord-
ance with VDI 2035, water/glycol mixtures in a ratio of 1:1.
When glycol is added, the output data of the pump must be ad-
justed based on the higher viscosity.
CAUTION!
Danger of damage to health!
The materials used in the pump can cause damage to health
as they are not approved for use in domestic water circulating
systems. The pump is not approved for use in pure domestic
water systems.
10 m³/h, see characteristic curve
12 m, see characteristic curve
1~230 V ±10 % according to DIN IEC 60038
0.16 - 1,37 A
50/60 Hz
F
IP X4D
16 - 310 W, see characteristic curve
see cap. 5.1 Model code
see cap. 5.1 Model code
Table 5.2 on page 4
 95 %
English
EN-3

Advertisement

Chapters

Table of Contents
loading

Table of Contents