Heatup 1400 Technical Data - Steinbach heatUP 650 Original Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

heatUP 1400 technical data

Model:
Item number:
Compressor type:
Total weight (net):
Dimensions (W x H x D):
Heating output*:
Heating input power*:
Heating input current*:
Cooling output*:
Cooling input power*:
Cooling input current*:
Operating voltage and frequency**:
Maximum input current:
Maximum input power:
Coefficient of performance (COP):
Energy efficiency ratio (EER):
Protection class:
IP rating:
Sound power level:
Heat exchanger material:
Water throughput:
Air throughput:
Nominal suction pressure:
Maximum suction pressure:
Nominal feed pressure:
Maximum feed pressure:
Coolant:
Maximum coolant fill quantity:
Global warming potential (GWP):
heatUP 1400
049253
Gree rotary compressor
62 kg
985 mm × 660 mm x 310 mm
14.0 kW
2.35 kW
11.5 A
8.7 kW
2.65 kW
12.8 A
220-240 V~, 50 Hz
14.8 A
3.2 kW
6.0
3.5
I
IPX4
53 dB(A)
Titanium in PVC
min. 7 m
/h
3
2,700 m
/h
3
0.7 MPa
1.5 MPa
3.0 MPa
4.3 MPa
R32
900 g
675
77