Download Print this page

Idex Fluid Management AT1500HS Technical Support

Canister remapping

Advertisement

Quick Links

Fluid Management
AT1500HS Canister Remapping
PRODUCT(S)
AT1500HS
PURPOSE
This instruction is for all customers using Fluid Management's ColorPro 4.x. software.
Follow this procedure if the pump or agitation motor has failed and there is a spare
position available.
INSTRUCTIONS
1. Close the ColorPro program
2. Click on SERVICE.EXE bridge on your desktop
3. Enter password service
4. Click on Setup (F4)
5. Click on the Canister tab
6. Click on the spare to activate and click Enter on your keyboard
7. Wait for the pulse test to complete
8. The spare canister should be activated when the number box goes from black to
grey
9. Click on Options (F5)
10. Click on the color that is not dispensing
11. Rename it "Spare" under ingredient name
a. For example, if the "C" colorant is not dispensing, click on the "C" colorant
and rename it to "Spare"
12. Click Apply, then click OK to save the changes
13. Click on Options (F5)
14. Click on the spare canister position just activated
CTB-12
Reformatted document, re-released.
Technical Support
AT1500 Canister Remapping
6/27/19
Original Release

Advertisement

loading

Summary of Contents for Idex Fluid Management AT1500HS

  • Page 1 Fluid Management Technical Support AT1500HS Canister Remapping PRODUCT(S) AT1500HS PURPOSE This instruction is for all customers using Fluid Management’s ColorPro 4.x. software. Follow this procedure if the pump or agitation motor has failed and there is a spare position available. INSTRUCTIONS 1.
  • Page 2 15. Change the name of the spare to the color that was not dispensing a. For example, if the “C” canister is faulty, then rename the spare canister to “C” 16. Click Apply, then click OK to save the changes 17.
  • Page 3 41. Click on Manual 42. Select the colorant just remapped 43. Enter 10Y into the amount field type and dispense 10oz of colorant a. Place container under nozzle b. NOTE: the large dispenser is required to fill the tubing with colorant to prevent from having any air in the line 44.