LGMedSupply LG-200 Instruction Manual

Analog muscle stimulator

Advertisement

Quick Links

LG-200
Analog Muscle Stimulator
INSTRUCTION MANUAL
INSTRUCTION MANUAL
Distributed by:
LGMedSupply.com
PO Box 913
FDA 510K
www.lgmedsupply.com
V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LG-200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LGMedSupply LG-200

  • Page 1 LG-200 Analog Muscle Stimulator INSTRUCTION MANUAL INSTRUCTION MANUAL Distributed by: LGMedSupply.com PO Box 913 FDA 510K www.lgmedsupply.com V1.0...
  • Page 2: Table Of Contents

    INDEX Chapter Contents Page Index ..............1 Introduction ............2 Cautions ..............3 Warnings ............... 4 Contraindication ..........4 Adverse Reactions ..........5 General Description ........... 5 Construction ............5 Technical Specifications ........6 Replaceable Parts ..........7 10 . Accessories ............7 11 .
  • Page 3: Introduction

    Chapter 1 : INTRODUCTION Then when the pulse ceases, the muscle relaxes and the cycle starts over again,(Stimulation, Contraction and Relaxation.) Powered muscle stimulators should only be used under medical supervision EXPLANATION OF EMS for adjunctive therapy for the treatment of medical diseases and Electrical Muscle Stimulation is an internationally accepted and proven conditions.
  • Page 4: Warnings

    Chapter 6 : GENERAL DESCRIPTION Chapter 3 : WARNINGS The LG-200 Analog Muscle Stimulator is a battery operated pulse 1. The long-term effects of chronic electrical stimulation are generator that sends electrical impulses through electrodes to the unknown.
  • Page 5: Replaceable Parts

    Chapter 10 : ACCESSORIES 12 Ramp Time 1, 3 or 5 seconds 13 Operating Temperature : 0°~40°C Each set LG-200 are completed with standard accessories as given Condition Relative Humidity : below 30%~75%Atmosphere Pressure : 700Hpa~1060Hpa 14 Remark REF. NO.
  • Page 6: Graphic Symbols

    3-4 uses. If you are unsure of your electrode adhesive WIRES properties, order replacement electrodes. Replacement electrodes should be re-ordered through LGMedSupply.com (888-633-7360) to ensure proper quality. Follow application procedures outlined in The wires provided with the system insert into the jack sockets electrode packing, to maintain optimal stimulation and to prevent skin located on top of the device.
  • Page 7: Tips For Skin Care

    sites and the settings on the patient’s Reference sheet of this manual, Chapter 17 : APPLICATION OF RE-USABLE SELF so the patient can easily continue treatment at home. ADHESIVE ELECTRODES Application Chapter 16 : TIPS FOR SKIN CARE 1. Clean and dry the skin at the prescribed area thoroughly with To avoid skin irritation, especially if you have sensitive skin, follow soap and water prior to application of electrodes.
  • Page 8: Adjusting The Controls

    Important 3. On/Off Switch and Intensity Controls: If both controllers are in the off-position (white markings on the 1. Do not apply to broken skin. housing), the device is switched off. 2. The electrodes should be discarded when they are no longer By turning the controls clockwise, the appropriate channel is adhering.
  • Page 9: Battery Information

    This dial determines the time of relaxation. The stimulation ceases at set ting relaxation time and then re-start in a cycle pattern. The The LG-200 Analog Muscle Stimulator can be used relaxation time of both channels is changed by turning this dial.
  • Page 10 RECHARGEABLE BATTERIES (NOT INCLUDED) (d) WARNINGS: 1. Do not attempt to charge any other types of batteries in Prior to the use of a new unit, the rechargeable battery should be your charger, other than the nickel-cadmium rechargeable charged according to the battery manufacturer’s instructions. Before batteries.
  • Page 11: Safety Technical Controls

    - damaged or defective output sockets. 2. Check the device for defective operating elements. All LG-200 Analog Muscle Stimulator models carry a warranty of - legibility of inscriptions and labels. one year from the date of delivery. The warranty applies to the - make sure the inscriptions and labels are not distorted.

Table of Contents