LGMedSupply LG-3000 Instruction Manual

LGMedSupply LG-3000 Instruction Manual

Analog tens unit

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LG-3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LGMedSupply LG-3000

  • Page 2: Table Of Contents

    INDEX Chapter Contents Page Index ..............1 Introduction ............2 Cautions ............... 3 Warnings .............. 4 General Description ........... 5 Construction ............5 Technical Specifications ........6 Replaceable Parts ..........7 Accessories ............7 Graphic Symbols ..........8 10 . Parameter Controls ..........8 11 .
  • Page 3: Introduction

    patient feels. Pain relief varies by individual patient, mode selected Chapter 1 : INTRODUCTION for therapy, and the type of pain. In many patients, the reduction or EXPLANATION OF PAIN elimination of pain lasts longer than the actual period of stimulation (sometimes as much as three to four times longer).
  • Page 4: Warnings

    Do not use it in the presence of explosive atmosphere and flammable mixture. The LG-3000 Analog TENS Unit is a battery operated pulse generator that sends electrical impulses electrodes to the body and reach the nerves causing pain. The device is provided with two controllable Chapter 3 : WARNINGS output channels, each independent of each other.
  • Page 5: Technical Specifications

    Chapter 6 : TECHNICAL SPECIFICATIONS Chapter 7 : REPLACEABLE PARTS The technical specification details of LG-3000 Analog TENS Unit are as follows. The replaceable parts and accessories of T.E.N.S. devices are as given below-Except leads, electrodes and battery, battery case cover,...
  • Page 6: Graphic Symbols

    Despite above recommendations, these individual patients may Chapter 9 : GRAPHIC SYMBOLS require slight variations of the above settings, according to the nature of their condition. Note Operating Instructions TREATMENT MODE Degree of Electrical Protection BF Normal or Conventional TENS offers the practitioners complete control Do not insert the plug into AC power supply socket.
  • Page 7: Lead Wire Maintenance

    Replacement electrodes on top of the device. Holding the insulated portion of the connector, should be re-ordered through LGMedSupply.com (888-633-7360) to push the plug end of the wire into one of the jacks (see drawing); one ensure proper quality.
  • Page 8: Tips For Skin Care

    With a two channels application, the clinician may either direct the Chapter 16 APPLICATION OF RE-USABLE SELF current flow to cross through the pain site or, in what is called the ADHESIVE ELECTRODES “bracket” method allowing the current flow on either side of the painful area, generally through the nerve branches that feed into the pain site.
  • Page 9: Adjusting The Controls

    By turning the controls clockwise, the appropriate channel is Important switched on and the impulse display led will illuminate and begin to pulse according to the frequency set. 1. Do not apply to broken skin. 2. The electrodes should be discarded when they are no longer The current strength of the impulses transmitted to the electrodes adhering.
  • Page 10: Battery Information

    70-120 uS setting. Chapter 18 : BATTERY INFORMATION LG-3000 Analog TENS Unit can be used with a rechargeable battery when necessary. If you use rechargeable batteries, please follow the instructions.
  • Page 11: Of Tens Device

    (d) WARNINGS: RECHARGEABLE BATTERIES (NOT INCLUDED) 1. Do not attempt to charge any other types of batteries in your charger, other than the nickel-cadmium rechargeable Prior to the use of a new unit, the rechargeable battery should be batteries. Other types of batteries may leak or burst. charged according to the battery manufacturer’s instructions.
  • Page 12: Malfunctions

    STANDARDS For safety reasons, check your LG-3000 Analog TENS Unit each week based on the following checklist. The LG-3000 Analog TENS Unit devices are in compliance with EN60 601-1: 1990+A1:1993+A2:1995. 1. Check the device for external damage. - deformation of the housing.