External Dimensions/Valve Mounting Surface Dimensions - YUKEN KOGYO ELDFG-01EH 10 Series Instruction Manual

Direct operated and high response type proportional electro-hydraulic directional and flow control valves
Table of Contents

Advertisement

2.3 External dimensions/valve mounting surface dimensions

ELDFG-01EH-*-*-XY-*-*-10
Protective Screw for NULL Adjuster Hole
*1. For NULL adjustment, remove the protective screw and turn the trimmer behind the screw.
After adjustment, be sure to attach the protective screw.
*2. The 6 + PE connector is not included with the valve. Prepare it separately.
YUKEN parts number: TK290457-1
● Dimensions of Mounting Surface
Prepare the mounting surface as shown below. Basically, the dimensions of the mounting
surface conform to ISO 4401-03-02-0-94.
machined finish, e.g. surface roughness of 6-S.
Indicator Lamp
Cylinder Port "A" Tank Port "T" Cylinder Port "B"
*1
Pressure Port "P"
M5 (+) Thd.
6 + PE Connector
M5 Thd. 10 Deep
4 Places
7 Dia.
4 Places
Air Vent
3 Hex. Soc.
5.5 Dia. Through
9.5 C' Bore 4 Places
*2
Cable Applicable:
Outside Dia. 8 - 10 mm
Nameplate
Mounting Surface
(O-Rings Furnished)
The mounting surface should have a good
- 8 -
EM-1359
Color
Indicator Lamp
Green
Power Supply
Deviation Alarm
Red
● O-Rings for the Ports
AS568-012 (NBR, Hs90): 4 Pieces