4.2 Connection between the cable and the connector

The connector is not included with the valve. Prepare a connector that conforms to the
standard specified by YUKEN and wire it correctly by following the instructions for the
connector.
Connect the connector to the power supply and the setting adjuster via the recommended
cable with reference to the connector pin assignment shown in 2.5 or the installation
drawing.
For YUKEN's connector TK290457-1, see 4.2.1 "Assembly of the 6 + PE connector".
DANGER
4.2.1 Assembly of the 6 + PE connector
(YUKEN parts number:
Components
(1) Terminal Box
Assembly
1. Cable preparation
a. The applicable cable outside diameter is φ 8 to 10 mm.
b. The applicable lead wire size is 1.0 mm
c. Terminate the end of the cable as shown below.
Peel off the length of the cable sheath and the ends of the lead wires as shown above.
2. Wiring
a. Pass the cable through (6), (5), (4), (3), and (2) in this order in the direction of the arrow
in the figure above.
b. Solder the lead wires to the terminals in the terminal box (1). Then, tighten the screws
of the cable clamp (2) to hold the cable sheath securely.
c. Screw the housing (3) into the terminal box (1).
d. Put the packing (4) and the washer (5) into the housing (3). Then, tighten the cable
gland (6).
* The tightening force depends on the cable size. Tighten the cable gland so that no
gap is left between the cable and the packing.
Do not wire the connector while the power is on. Doing so may
cause electric shock, resulting in a fatal accident.
(2) Cable Clamp (3) Housing
TK290457-1)
(4) Packing
(5) Washer
2
(AWG17) or less.
- 14 -
EM-1359
(6) Cable Gland