blind/roller shutter module
GB
Installation instruction Compact

Important installation information !

• Read through the operating instructions carefully before putting the device into service!
• Only use 1-phase power supply with a 10A overload release. (terminal L, N  230V~/50 Hz)!
• Make sure the polarity of the motors is correct! After connecting the motors, switch to central UP. When not all of the motors move UP, check the motors'
connections and polarity!
• Auto mode for the outputs can be activated and deactivated at a switch on input I32 of the JRM module. This requires the corresponding outputs to be
assigned to input I32 (see AUTO MODE instructions).
caution !!
• Only one motor (max. 1A) may be connected to each output (e.g. motor M0: O0 = motor DOWN, O1 = motor UP)! The manufacturer's operating
instructions must be observed when installing the motors.
• Use separate connections for the control and motor lines! They may not be laid together in one wiring connection.
• Wiring connections must not run behind the JRM for EMC reasons!
• The 24V inputs are connected to the JRM's 24V supply voltage. Make sure that no connections are joined to any alternating current circuits (230V~).
This can cause a defect in the Compact JRM!
• The 24V supply voltage for inputs I0-I35 is provided by the module. Buttons or sensors are used to switch it to ground (0V terminals). The voltage
may only be used for this application! The separate sensor connection (terminal 0 and 24) must be used for operating voltages of 24 V!
• The wiring connections for supplying power (230 V~ /50 Hz) to the motors (terminals L0-L3) must be protected with a 10 A automatic circuit breaker.
Make sure the loads are evenly distributed!

ConneCTIon PossIbILITIes

0
1
L0
O0 O1
O2
O3
O4
O5 L0
O6 O7
O8
O9 O10
O11
L1 L1
µ
µ
µ
µ
M0
M1
M2
M3
M4
M5
µ
µ µ
µ µ
µ
µ
µ
compact
L
N
11
100-240 V ~
50-60 Hz
Status
12 x 1A
M
100-240V ~ / 50-60Hz
 Bus In
 Bus Out
952 JRM
I0
I1
I2
I3
I4
I5
I6 I7 I8
0V
I9
I10
I11
I12
I13
I14
I15 I16 I17
0V
10
10
connections
Three motors (M0-M2) can be connected to the output terminal block 0. Motors M0, M1, M2 can be connected
Terminal block 0
together, or M0 and M1 can be connected separately from M2 (e.g. for RCD protective switch). A phase leg
0
(Motor M0-M2)
(e.g. L1) must be connected to the L0 terminals to supply the motors with power (230V~/50Hz).
caution! The L0 terminals require the same potential!
A total of 9 motors (M3-M11) can be connected to output terminal blocks 1-3 (3 motors to each terminal
Terminal block 1-3
1-3
block). One of the phase legs (L1-L3) must be connected to each terminal block to supply the motors with
(Motor M3-M11)
power (230 V~ /50 Hz).
4
Wind sensor / rain sensor 24V-input for Wind and/or rain sensor.
5
Sun sensor S1
24V-input for sun sensor S1.
6
Twilight sensor
24V-input for twilight sensor.
7
Automatic
24 V input for a switch to activate/deactivate auto mode.
24V inputs for connecting 3 dual buttons for the UP/DOWN function in group 0-2.
8
Pushbutton mode Group
Attention! The "Sensors" setting deactivates Group 2! The inputs I30 and I31 for Group 2 are then available
for connection to a sun sensor S2/S3.
9
Pushbutton mode Central 24V-inputs for connection of 1 double button for the central UP/DOWN function
10
Pushbutton mode Local
24V-inputs for connection of 12 double buttons for the local UP/DOWN function
11
Main supply
Operating voltage connection (100-240V~/50-60Hz).
12
Bus connection
Bus port for data link between modules (see COMPACT BUS instructions).
13
Sensor connection
Supply voltage for sensors (24V DC /100 mA).
PEHA_M_Installation_952JRM (Rev01-130308)
952 JRM
2
3
O12
O13 O14
O15
O16 O17
L2
L2
O18
O19
O20 O21
O22
O23 L3
M6
M7
M8
M9
M10
M11
µ
µ µ
µ µ
µ
µ
µ µ
µ µ
µ
Compact
14:14
17.10.2012
12
13
24V
100mA
PROG
0 24
36 x Input 24V
I18
I19
I20
I21
I22
I23
I24 I25 I26
0V
I27
I28
I29
I30
I31
I32
I33 I34 I35
9
8
7 6
5 4
Description

ConneCTIon DIagRaM

terminal block 0
N
N'
FI
M0
L1'
F
L0
O0 O1
L3
µ
M0
µ µ
9 mm
compact
12 x 1A
M
100-240V ~ / 50-60Hz
ENTER
952 JRM
I0
I1
I2
I3
0V
terminal
O0-O5
O6-O23
I35
I34
I33
I32
I26-I31
I24-I25
I0-I23
L, N
Bus In/Out
0, 24
terminal block 1
L1
L1
M1
M2
M3
M4
M5
F
F
O3
O5 L0
O6 O7
O8
O9 O10
O11
L1 L1
O12
O2
O4
µ
µ
µ
µ
M1
µ µ
M2
µ
M3
M4
µ
M5
µ
µ
L
N
100-240 V ~
50-60 Hz
Status
 Bus In
 Bus Out
36 x Input 24V
I4
I5
I6 I7 I8
0V
I9
I10
I11
I12
I13
I14
I15 I16 I17
0V
I18
terminal block 2
terminal block 3
Switches
Buttons or
Sensors
L2
L3
M6
M7
M8
M9
M10
M11
F
F
O13 O14
O15
O16 O17
L2
O23 L3
L2
O18
O19
O20 O21
O22
L3
M6
µ µ
M7
µ µ
M8
µ
µ
M9
µ µ
M10
µ µ
M11
µ
Compact
14:14
17.10.2012
24V
100mA
PROG
ENTER
0 24
I19
I20
I21
I22
I23
I24 I25 I26
0V
I27
I28
I29
I30
I31
I32
I33 I34 I35
0V
9 mm
GB - 1

Advertisement

Table of Contents
loading

Table of Contents