 Connect the probe output to the TA4000
oscilloscope before connecting the probe to the
circuit under test. Disconnect the probe input and
the probe reference lead from the circuit under test
before disconnecting the probe from the TA4000
oscilloscope.
 To avoid fire or shock hazard, observe all ratings
and markings on the product to be tested. Consult
the product manual for rating information before
making connections to the product. To avoid shock
hazard, use a correctly rated probe for your
measurement.
 Remain vigilant when using the oscilloscope and
associated cables on, or near, machinery where
there are rotational parts such as belts, pulleys and
fans.
 Maintain correct balance and footing. Ensure the
floor is not slippery and wear non-slip shoes.
 Remove ill fitting clothing. Remove ties, watches,
rings, and other loose jewellery, and contain and/ or
tie back long hair.
Original Language Version
INSTRUCTIONS FOR:
HT IGNITION PROBE
MODEL No:
 DO NOT touch exposed connections and
components when power is on.
 DO NOT connect or disconnect probes or test leads
whilst they are connected to a voltage source.
 Read and understand the manual for the TA4000
oscilloscope before using this cable set.
2. INTRODUCTION
The TA4000.06 Hi Tension Probe Lead Set is a type of
inductive capacitance probe intended for use
exclusively with the TA4000 Oscilloscope. Its purpose
is to help diagnose engine ignition system problems. It
works by displaying a waveform corresponding to
voltage against time for a cylinder cycle.
To avoid the risk of fire or electric shock, ensure that
the test clip is connected to the ignition lead and not
directly to the ignition plug itself.
To avoid interference the probe cable should be at
least 50mm away from any high voltage wires.
TA4000.06
TA4000.06
Issue: 1 - 21/09/11