7.7 Decommissioning

1. Close the valves on the supply pipes.
2. Drain the tank by pressing the forced mode button on the pump.
3. Close the discharge valve
4. Switch off the electrical power supply and record the installation.
The current is not switched off. Risk of electric shock!
➜ Disconnect the plug or disconnect the electrical conductors and take measurements
5. Inspect the hydraulic parts and shredding blades. Clean them if necessary.
6. Clean the tank
Pumped fluids harmful to health. Dangerous for people and the environment!
➜ Pumping stations used to discharge fluids that may be harmful to health must be
decontaminated.
If necessary, wear a mask and protective clothing.

8. MAINTENANCE

8.1 General information / Safety instructions

Pumped fluids harmful to health. Dangerous for people and the environment!
➜ Pumping stations used to discharge fluids that may be harmful to health must be
decontaminated.
If necessary, wear a mask and protective clothing.
Work performed on the pumping station by unqualified staff. Risk of injury!
➜ Repairs and maintenance must be performed by specially trained staff.
➜ Observe the safety and basic instructions.

8.2 Maintenance and inspection operations

Work on the pumping station without adequate preparation.
Risk of injury!
➜ Properly stop the pumping station and secure it against inadvertent operation.
➜ Close the inlet and discharge valves.
➜ Drain the pumping station.
➜ Close any auxiliary connections.
➜ Allow the pumping station to cool to room temperature.
WARNING
WARNING
WARNING
WARNING
29