Advertisement

Quick Links

LOGIFLEX ROTATOR - SELFR / SELFSR

Advertisement

Table of Contents
loading

Summary of Contents for logitrans LOGIFLEX SELFR

  • Page 1 LOGIFLEX ROTATOR - SELFR / SELFSR...
  • Page 2 EU DECLARATION CONFORMANCE Logitrans A/S Manufacturer: Hillerupvej 35 DK-6760 Ribe Danmark It is hereby declared that: Machine: Productgroup: Logiflex with Rotator Type: SELFR/SELFSR Year of manufacture/ Serial No: a) Has been manufactured in conformance with the stipulations of the: • COUNCIL DIRECTIVE no. 98/37/EC • COUNCIL DIRECTIVE no. 89/336/ECC b) Has been manufactured in conformance with the stipulations of the standard: • EN-1757-1 Name:...
  • Page 3: Table Of Contents

    Contents 1.0 Before the first lift....................4 2.0 Functions and identifications ................5 2.1 Box holder ........................... 6 2.2 Box holder with clalmps ....................... 6 3.0 How to operate the Logflex with Rotator ..........7 3.1 Handling of pallets ....................... 7 3.2 Emergency stop........................8 3.3 Handle functions ........................
  • Page 4: Before The First Lift

    1.0 Before the first lift... Logiflex with Rotator is manufactured in accordance with safety directives. Among other subjects dealt with in this Instruction Manual are: • Proper application • Psysical limitations of the product • Risks with improper use Therefore please read this Instruction Manual carefully!
  • Page 5: Functions And Identifications

    2.0 Functions and identifications 1. Safety switch Remote control 2. Horn 3. Lift/Lower 4. Forward/Reverse 5. Multiflex function 6. Handle 7. Battery indicator / hour counter 8. Emergency stop 9. Ignition key 10. Charger plug (external charger) 11. Box holder with clamps 12. Box holder without clamps 13. Battery label (below the cover) 14. Name plate, serial number 15.
  • Page 6: Box Holder

    2.0 Functions and indentifications 2.1 Box holder The rotator can be equipped with one or two sets of box holders, adjusted for different box sizes. When loosening the screw (A), the box holder can be moved between the two different positions. NOTE! The screw has to be tightened, before using the product. Adjusting the distance • Fork span 560mm: For box widths of 800, 850 or 1000mm. • Fork span 680mm: For box widths of 1000, 1050 and 1200mm. Setting of height The box holders can be placed in two different heights • I t is important that the box holders are placed approx. on the level of or above the load centre of the load. • I f possible, use two box holders in each side 1) When the weight of the load is between 800 and 1000 kg. 2) For high boxes or when the material of the box is unstable, e.g. cardboard NOTE! If the box holders have no clamps, the load is not allowed to be tilted more than 60º to each side. 2.2 Box holders with clamps If the box can fall off, or if it has to be tilted more than 60º, box holders with clamps have to be used.
  • Page 7: How To Operate The Logflex With Rotator

    3.0 How to operate Logiflex w/Rotator 3.1 Handling of pallets The Logiflex with Rotator functions as an ordinary stacker, when the forks are placed in horizontal position. For proper operation, stand behind the handle. Push/pull - raise/lower SELFSR When handling closed pallets - use the straddle Logiflex! SELFR...
  • Page 8: Emergency Stop

    3.0 How to operate the Logiflex with Rotator Insert key (1) and turn clockwise to switch on control current ready for function activation. Note!!! Emergency stop (2) must not be activated. 3.2 Emergency stop The product has an emergency stop. When activating the emergency stop, the main current supply is switched off. • The movement of the forks stops immediately • Driving with the truck stops immediately • The emergency stop is deactivated by turning the switch to the right...
  • Page 9: Handle Functions

    3.0 How to operate the Logiflex with Rotator 3.3 Handle functions...
  • Page 10 3.0 How to operate the Logiflex with Rotator Multiflex function Multiflex function • This function makes it possible to drive the stacker, even though the handle is in its upright, braked position (B) • The function requires two-handed operation, i.e. it must be performed deliberately • The function facilitates manoeuvring in confined areas. The control functions of the stacker are located in the handle (3). - The functions are dependent on the positions of the handle! Position A: Drive position Drive current on Brake deactivated Position B: Stop/Brake/...
  • Page 11: Personal Safety

    3.0 How to operate the Logiflex with Rotator 3.4 Personal safety The safety switch on the end of the handle ensures that the operator cannot be trapped when the stacker is reversed. When the safety switch is activated, the stacker will change direction, move forwards and stop. Safety function ...
  • Page 12: Use Of The Rotator

    3.0 How to operate the Logiflex with Rotator 3.5 Use of the Rotator Condition: The upper edge of the forks is lifted between 400 and 900 mm. The load can be rotated 355º with one adjustable stop in every side. Note! To continue the tilt function from the horizontal position, the tilt switch has to be released and activated in the requested tilt direction. NOTE! The load has to be supported sideways before tilting. To lower the forks or to lift higher than 900 mm, the forks have to be placed in horizontal position. Soft acceleration / deceleration The Rotator has soft acceleration / deceleration with the following benefits: • The rotation stops precisely • The gear is protected, because sudden start / stop are minimised...
  • Page 13: Adjusting Of Stop

    3.0 How to operate the Logiflex with Rotator 3.6 Adjusting of stop The forks are factory-set to stop in 45º. If another setting is required, the Rotator can be set electronically to stop in different angles. 1) The forks are placed in horizontal position 2) Short pressure on the switch A activates the setting procedure. The controller gives a signal (one beep) 3) The forks are placed in the requested angle 4) When the forks have reached the requested angle, the controller will give signal after three seconds (one beep), when the position has been stored. The procedure is repeated to set stop in the other side. 3.7 Setting the speed Plug from remote control...
  • Page 14: Optimum Safety

    4.0 Optimum safety ATTENTION Moving parts Safety regulations - Never walk under a raised load! - Before lowering the forks, make certain that no foreign elements can hinder the free lowering of the forks. - The Logiflex is designed for use on an even and level floor - During transport the forks shall be raised as little as possible - Transport with raised forks should be made over the shortest possible distances and at low speed - Check that the chains lift equally. They shall be equally tight when the forks are loaded - Chains and chain bolts must not be damaged. Chains that have become permanently stretched (max. 2 % of original length) must be scrapped..
  • Page 15: Avoid Overloads

    4.0 Optimum safety 4.1 Avoid overloads The maximum load must not be exceeded. Remember, that the Logiflex with Rotator is designed for evenly distributed load, - goods on pallets etc. If the forks are point-loaded on one side, there is a risk of bending. NOTE! When driving with the truck, the forks should be placed in horizontal position. Max. capacity of the Rotator/Multi-purpose carriage: 1000 kg / 700 Nm (see load diagram). Load diagram When the forks are tilted, the spatial position of the load changes. This means that the load capacity that can be tilted is reduced, the larger the distance is between load centre of the load and rotation centre.
  • Page 16: Avoid Offset Loads

    4.0 Optimum safety 4.2 Avoid offset loads The load must be evenly distributed. The maximum centre of gravity distance from the front of the fork mast (given on the truck) must not be exceeded. A greater distance reduces the level of safety and increases the risk of tilting. Goods on pallets, etc. must be properly secured, so that they cannot fall off during transport, when the truck is lifted, or when the truck must remain lifted for a time. Marking The mast lifting capacity and the corresponding centre of gravity distance are given by the pictogram on the side of the mast.
  • Page 17: Rotation Range

    4.0 Optimum safety 4.3 Rotation range Standard version The load can be rotated, when the upper edge of the forks are lifted between 400 and 900 mm. Outside this range, the stacker functions as a standard stacker. Top stop Indicates that the forks are lifted 900 mm above the floor. NOTE: Top stop is only placed on stackers with lifting heights, being higher than: 920 mm SELFR 890 mm SELFSR Bottom stop...
  • Page 18 4.0 Optimum safety Special version The top stop can be set to other intervals than between 400-900 mm. The height of the top stop depends on the width of the stacker, as a wide stacker can manage a larger sideways movement. E.g. On a stacker with 850 mm straddle legs, the stop can be placed at a maximum fork height of 1880 mm. Normal range for the maximum load 1000 kg /700Nm, fork height 400-900 mm. Range of maximum load 1000 kg /700Nm of stacker in special version Upper edge forks 1880 1450 Max. sideways moment Max. sideways SELFS 560x1250 with moment Max. sideways 850 mm straddle legs SELF 680x1250 moment SELF 560x1250...
  • Page 19: Driving Loaded

    4.0 Optimum safety 4.4 Driving loaded The load centre is never allowed to exceed the centre line of the wheels. The driving speed is reduced when lifting the forks above 400mm. 4.5 Rotation with load The load centre is not allowed to be placed on the outside of the legs of the stacker, as this will cause a risk of turning over. NOTE! Rotation is only allowed to take place, if the stacker is placed on an equal floor. The load is not allowed to be dislocated during rotation. When rotating boxes, the operator needs a full overview of the whole working area, so that the rotation movement can be stopped before the box touches the floor, the items or persons in the working area.
  • Page 20: There Must Be A Current Supply

    5.0 There must be a current supply... 5.1 Fuses - replacement There are five fuses in the electrical circuit. 80 Amp fuse in the main supply from battery 5 Amp fuse in the control current circuit 10 Amp fuse for built-in charger 40 Amp fuse for Rotator 60 Amp fuse for the hydraulic pump Replacement:...
  • Page 21: Long Live The Logiflex With Rotator

    6.0 Long live Logiflex with Rotator Regular inspection and the replacement of worn or defective parts in good time will prolong the life of the Logiflex. “Prevention is better than repair”, therefore ensure: • Check battery every 14 cycles • Correct usage • Regular cleaning • Periodic safety and service inspection (see the back page) • Due to safety reasons, the below points have to be checked every 3 months: - Loose screws and nuts have to be tightened up. - Breaches, cracks or deformations are not allowed on the load-bearing parts. - Wearing parts, such as brakes, wheels and bearings, are to be adjusted or changed continuously 6.1 Lubrication and hydraulic oil Under normal operation conditions the Logiflex requires no lubrication. All ball bearings are sealed and lubricated for life, and moving parts have self-lubricating bearings or are treated with grease.
  • Page 22: Oil Change

    6.0 Longe live Logiflex with Rotator 6.2 Oil change Draining the oil: 1. Bring the unloaded forks down to the lowest position. 2. Most of the oil can be drained by loosening the hydraulic hose union and briefly activating the hydraulic pump with the switch. 3. The remaining oil can be drained from the oil tank by taking off the oil tank. Oil filling: 4.
  • Page 23: Forks Adjustment

    6.0 Longe live Logiflex with Rotator 6.3 Fork adjustment Two of the rollers on the fork bracket are mounted on eccentric pins, so that they can be adjusted. The adjustable rollers are at the top. 1. Loosen screw (pos. 91) (key width 5 mm). 2. Eccentric pins (pos. 56) (key width 8 mm) can now be turned to give the necessary fork adjustment. 3. Adjustment must be made on both sides to ensure uniform loading of the rollers.
  • Page 24: Hydraulic Pump And Gear Motor

    6.0 Longe live Logiflex with Rotator 6.5 The hydraulic pump and the gear motor The hydraulic pump has a S3 “periodic intermittent duty” of 10%. This means that the pump in total is allowed to operate 1 minute for a period of 10 minutes. NOTE! If the pump operates more than 10%, the motor will be damaged due to superheating. Bleeding the hydraulic system With a load of 50-100 kg, the forks must be raised and lowered to top and bottom position 2-3 times. Gear motor of Rotator The gear motor has a ”short time under constant load” of 10 minutes (S2=10 minutes). This means that the motor is allowed to operate with the maximum load for 10 minutes. Hereafter it has to be cooled down to normal temperature. NOTE! The motor will be damaged by superheating, if it operates for a longer time or if it is not cooled down. 6.6 Cleaning When cleaning the Logiflex, do not direct the jet onto bearings, seals and electric components. Cleaning of the plastic screen (polycarbonate) The screen is to be washed with slightly warm water added a neutral cleaning material, and afterwards washed with clean water. Use a soft sponge, a woollen cloth or a wash leather. Never use sharp objects or solvent cleaners when cleaning.
  • Page 25: Adjustment Of Side Play

    6.0 Longe live Logiflex with Rotator 6.7 Adjustment of side play (In the mast rolls of the right side of the fork bracket) 1. Screw (A) is loosened counter-clockwise, until resistance disappears. 2. Turn the screw clockwise, until resistance appears. The following 1.5 to 2.5 turns of the screw will be a tightening of the spring (C). 3. When a larger resistance appears, make 0.25 turn counter- clockwise, and the counter nut (B) will be tightened. 4. Pump the forks to the top position, and when lowering it has to slide to the bottom. If this is not the case, loosen screw A, make c. 0.5 turn counter-clockwise and repeat point 4. Mast roll Fork C profil (mast)
  • Page 26: Adjustment Of The Rotator

    7.0 Adjusting the Rotator 7.1 Tensioning the chains When the unloaded forks can be tilted manually approx. 5 cm to the side, the chains should be tensioned. 1) Removing the cover from the tilt unit. 2) Loosening the gear motor (A1) 3) Loosening chain wheel (B1) 4) Turning the nut (B2), so that the fork chain is tensioned, until the slack is about 5 mm. 5) Tightening the chain wheel (B1) 6) Tightening the nuts for the gear motor (A2), so that the chain is tensioned, until the slack is about 2-3 mm. Tighten the nuts (A1) again. 7) Replace the cover. NOTE! Check the location of the inductive switch (see 7.2) and check that the fork chain is tighened correctly in the whole rotation area after adjusting the chains. Axle for gear motor Axle for chain wheel...
  • Page 27: Adjusting The Switch

    7.0 Adjusting the Rotator 7.2 Adjusting the switch The location of the forks is decided by two inductive switches. A) I nductive switch on thrust ring Indicates when the forks are in horizontal position. When the forks are in horizontal position, the inductive switch has to be placed right above the plate on the thrust ring in a distance of 2-4 mm. B) I nductive switch on the teeth of the little toothed wheel The number of the impulses indicates the angle of the forks. The distance from the inductive switch to the tooth has to be 2-4 mm.
  • Page 28: Fault Location Key

    8.0 Fault location key When the Logiflex is used every day, adjustments and the replacement of worn parts might be necessary. Adjustments and minor repair can easily be made on the spot. Major repairs should, however, be carried through by the dealer whos has a well-trained staff and the necessary special tools. Before asking the dealer for assistence..try the fault location key! SYMPTOMS AND OBSERVATIONS Pump does not run when the UP button is pressed Truck does not lift when the UP button is pressed Truck does not lift to max. height Forks fall after being raised Forks do not not fall when DOWN button is pressed Forks cannot be lowered fully Trucks is unable to lift the max. load...
  • Page 29 Cause Remedy See point 6.1/6.2 Oil deficiency See separate Battery discharged instruction Fuse blown See point 5.1 5 Amp or 80 Amp Cables defective See point 5.2 See point 4.1 Max. load exceeded Air in hydraulic system See point 6.5 Pressure relief valve Contact incorrectly adjusted the dealer Leakage in hydraulic system Contact...
  • Page 30: Good Service After Purchase

    • replacements of parts have been made incorrectly or original parts have not been used and consequential damages have arisen, • if the product is changed or accessories, not being approved by Logitrans, are used. • i t can not be proved that a qualified technician has performed the service check according to the requirements stated in the instruction manual (see the back page).
  • Page 32 Periodic service check Service check is required once each year. The service check is to be performed on the basis of form no. B280 and proved on form no. B284. Forms and instructions for the service check are available at your dealer. Periodic safety inspection Safety inspection should be performed by the dealer or other qualified persons at least once each year, unless local regulations state...

This manual is also suitable for:

Logiflex selfsr

Table of Contents