Direct Drive Motor Specifications and Instruction Manual
2 Specifications
[ TM-RBP105G10 ]
Power supply lead : 3-AWG10 (Finish outer diameter
(U, V, W)
Thermistor lead : 2-AWG18 (Finish outer diameter
(MT1, MT2)
Lead-out range
Ground lead : 1-AWG10 (Finish outer diameter
of lead wire
Recommended inlet/outlet
position for cooling liquid
8-M6 screw
(Note 1) Do not move the stator by holding the lead wire.
(Note 2) Degree of protection is IP00. Use explosion-proof oil, etc., as necessary.
(Note 3) Continuous rated torque is assured only when the required cooling capacity is satisfied.
(Note 4) There is no problem on the functionality or performance even if the molded parts include sink marks or voids, etc.
[ TM-RBS105G10 ]
(Note 1) Deliverable rotors are magnetized. Please note the magnetic attraction.
(Note 2) Take special care for the magnet part not to hit against a thing (A crack or chip may occur).
(Note 3) Degree of protection is IP00. Use explosion-proof oil, etc., as necessary.
(Note 4) There is no problem on the functionality or performance even if the molded parts include sink marks or voids, etc.
4.3)
2.3)
Effective length
300
4.73)
Recommended inlet/outlet
position for cooling liquid
35
20
Wire mark
Depth 14
MT1
MT2
U
V
W
(250)
(Wire mark position)
(13)
Rotor
(TM-RBS105G10)
8-M6 screw
Depth 14
105
35
20
(65: Cooling groove)
1
A
18.3
(20)
91
20
2
15
8-M6 screw
Depth 14
1
Detail A
8-M6 screw
Depth 14
IB-1501068-C
[Unit:mm]
[Unit:mm]