Download Print this page
A.O. Smith MEV 50 EC Instruction Manual

A.O. Smith MEV 50 EC Instruction Manual

Advertisement

Quick Links

MEV 50 EC, MEV 80 EC, MEV 100 EC, MEH 50 EC, MEH 80 EC, MEH 100 EC
INSTALLATION INSTRUCTIONS
Installation of the water heater shall be done by a qualified technician.
It is recommended to install the water heater as near as possible to the hot water faucets.
Place the water heater in such a manner that it is accessible for maintenance and cannot cause damage in case of leaking.
Before connecting the water heater to the water supply pipes, let the water flow for a few minutes to clean the water supply from
any foreign material that may have entered the water pipes.
Water supply pressure should be less than 8 bar. If water pressure is higher, install a suitable pressure regulator.
Connect the safety valve/check valve to the inlet pipe (blue). Connect the cold water supply to the safety valve.
The safety valve can drip during the heating cycle of the water heater to relieve excess water due to heat expansion. Provisions for
draining the relieve water should be made by using a funnel to collect dripping water, so drain is always open to the atmosphere
and cannot ever be blocked. Make sure the drain pipe is in continuously downward direction and in a frost free ambient.
Connect the hot water pipe to the hot water outlet (red).
Connection to the power supply shall be via a three core cable at least 1.5 mm
ELECTRICAL CONNECTION diagram).
Open the cold water supply line. The water heater is completely filled with water when water flows uninterrupted from the hot
water faucets.
When the water heater is completely filled, close the hot water faucets and switch on electricity supply.
MAINTENANCE AND CLEANING
Check proper functioning of the safety valve every two months by opening and closing the test lever. The heating element should be
checked annually for scale formation, caused by impurities in the water supply. Also the anode should be checked annually and replaced
when worn for more than 60%. For cleaning the element or replacing the anode follow following procedure:
1.
Switch off the electric supply to the water heater
2.
Open the hot water taps until water is not hot any more
3.
Close cold water supply
4.
Put a vessel of suitable capacity under the water heater
5.
Drain the water heater by removing the bottom cover, unscrew the heating assembly flange and allow the water to fall in the
vessel
6.
Clean the container and the heating unit assembly from scale by using a suitable acid or by gently scraping of the scale.
7.
Replace anode if required
8.
Remount the heating assembly flange
9.
Open cold water supply until water flows without interruption from hot water faucets 10. Close the hot water taps and check
for eventual leakage around the flange 11. When there is no leakage, replace cover. Then switch on electric supply.
12.
The pressure relief device is to be operated regularly to remove lime deposits to verify that it is not blocked.
Warranty
1.
If within one year after initial installation date any part or component other than the tank shall prove defective in material or
workmanship upon examination by A.O. Smith or local authorized agent, A.O. Smith will repair or supply such part or component
through the local agent.
2.
It within five years after initial installation the tank fails due to rust or corrosion from the water side, A.O. Smith will supply a new
water heater of equivalent size and capacity. Delivery and installation charges are not included in this warranty. The replacement
water heater will be granted warranty for the unexpired part of the warranty of the originally installed water heater.
3.
The warranty only applies if:
a.
The water heater has been installed as per the above instructions
b.
Maintenance has been carried out as per above instructions
c.
Safety valves and anodes have been kept in working condition
4.
The warranty is void if:
a.
The tank has been damaged by external causes
b.
In case of misuse, neglect or incorrect use of the water heater
c.
In case of use with non potable water or water softened to less than 60 ppm CACo3
d.
In case of unauthorized alteration, modification or repair.
INSTRUCTION MANUAL
MODELS:
2
. One of the cores is for earth connection (see

Advertisement

loading

Summary of Contents for A.O. Smith MEV 50 EC

  • Page 1 It within five years after initial installation the tank fails due to rust or corrosion from the water side, A.O. Smith will supply a new water heater of equivalent size and capacity. Delivery and installation charges are not included in this warranty. The replacement water heater will be granted warranty for the unexpired part of the warranty of the originally installed water heater.
  • Page 2 INSTRUCTION MANUAL MODELS: MEV 50 EC, MEV 80 EC, MEV 100 EC, MEH 50 EC, MEH 80 EC, MEH 100 EC Trade mark: A.O. Smith ELECTRICAL CONNECTION Manufacturers no.: MEV/MEH Rated Voltage 230 Volt 50/60Hz Rated input 2000/2500 Watts 1-Thermostat setting knob...

This manual is also suitable for:

Mev 80 ecMev 100 ecMeh 50 ecMeh 80 ecMeh 100 ec