Chengdu Ebyte Electronic Technology Co.,Ltd.
7.4.5 AT+PARITY, Parity Setting
Query
AT+PARITY?
Format
AT+PARITY=[parity]
data
note
Reboot to take effect, save when power off
example
AT+PARITY=0, no parity
7.4.6 AT+HWFC , Serial flow control
Query
Format
data
note
example
7.4.7 AT+LINK , Communication link setting
Query
AT+LINK?
Format
AT+ LINK =[para]
Para: Communication link. The value range is 1 to 9999, and the default value is 1
data
Take effect immediately (and automatically restart), save when power off;
note
example
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
Command
Parity
0
1
2
Command
AT+HWFC?
AT+ HWFC =[para]
Para
0
1
Reboot to take effect, save when power off
AT+HWFC=0
Command
Reply
+OK=[ parity]
+OK:Success
+ERR=[NUM]:error
Description
No Parity (default)
Even parity
Odd parity
Reply
+OK=[para]
+OK:success
+ERR=[NUM]:error
Description
Flow control off (default)
Flow control on
Reply
+OK=[para]
+OK:success
+ERR=[NUM]:error
E90-DTU(2G4HD12) User Manual
18