10. As part of a routine maintenance schedule, the condition of the window cement shall be
periodically inspected for any degradation or discolouration of the cement that may
compromise the explosion protection.
11. As per IEC/EN 60079-14 the ID5002P shall be either isolated from earth or connected at
one point to the equipotential bonding system.
12. If enclosure equipotential bonding or earthing is connected then to avoid double earth
faults the EXTSW connection must not be connected to a second earth.
PARAMETER TABLES:
The ID5002P must be connected via suitably certified intrinsically safe barriers satisfying the
following parameters unless otherwise stated:
Description
Power
Supply
Terminals
VIN
0V
Ui
21.5V
Ii
604mA
Pi
3243mW
Ci (int)
0μF
Li (int)
0μH
Uo
-
Io
-
Po
-
Co (ext)
-
Lo (ext)
-
Example
GM
Accessory
PSD5201
NOTE3
Description
Relay
NO1
COM1
NC1
Terminals
NO2
COM2
NC2
Ui
15.0V
Ii
2000mA
Pi
7500mW
Ci
0μF
Li
0μH
Example
MTL
Barrier
7758+
NOTE4
NOTE1
The ID5002P is supplied with a suitable internal switch.
NOTE2
The ID5002P is supplied with a suitable sensor.
NOTE3
Use only barriers or accessories supplied or approved by Online Electronics Ltd.
ID5002P MANUAL RevA01
RS485
4-20mA
Current
Loop
RS485+
CL+
RS485-
CL-
RS485GND
6.0V
29.4V
600mA
125mA
450mW
920mW
110nF
121nF
0μH
0μH
-
-
-
-
-
-
-
-
-
-
MTL
MTL
7755ac
7787+
21.6V
611mA
3299mW
0μF
OR
OR
0μH
MTL
7715P+
Internal
External
Switch
Switch
INTSW
EXTSW
0V
0V
-
0V
NOTE1
-
0mA
NOTE1
-
0W
NOTE1
-
0μF
NOTE1
-
0μH
NOTE1
-
4.1V
NOTE1
-
5mA
NOTE1
-
5mW
NOTE1
-
10uF
NOTE1
-
0.2H
NOTE1
GM
NA
NOTE1
D1044S
24.0V
30.0V
433mA
253mA
2958mW
1897mW
0μF
0μF
OR
0μH
0μH
MTL
MTL
7715P+
7787P+
Remote
Sensor
Switch
TRIG+
SEN+
TRIG-
SEN-
29.4V
-
125mA
-
650mW
-
0μF
-
0μH
-
-
23.1V
-
28mA
-
160mW
-
1.02μF
-
0.19H
MTL
NA
NOTE2
7787+
45.0V
113mA
1271mW
0μF
OR
0μH
MTL
7787+
Page 21 of 21