SLIM
QUICK REFERENCE GUIDE
This Quick Reference Guide does not replace the Instruction Manual.
Download the Instruction Manual by reading the QR code here or at
www.datalogic.com. Click on Support > Search by product and enter
the SLIM family name, then select your product from the dropdown list.
Click on the Manuals & Technical Literature link to download your
Instruction Manual. The Instruction Manual must be available at all
times when installing and working with the product.
Scan or tap on the QR code
to download the Instruction
Manual.
Safety Light Curtains

Advertisement

loading

Summary of Contents for Datalogic SLIM

  • Page 1 Download the Instruction Manual by reading the QR code here or at www.datalogic.com. Click on Support > Search by product and enter the SLIM family name, then select your product from the dropdown list. Click on the Manuals & Technical Literature link to download your Instruction Manual.
  • Page 2: Safety Information

    SAFETY INFORMATION For a correct and safe use of the safety light curtains of the SLIM series, the following points must be observed: CAUTION • The stopping system of the machine must be electrically controlled. • This control system must be able to stop the dangerous movement of the machine within the total machine stopping time T as per paragraph “Minimum installation distance”...
  • Page 3 Cascade connection Up to three SLIM light curtains can be connected in a cascade series. The cascade connection allows to monitor up to three areas with only two Safety Outputs connected to Master unit. Master unit takes care of collecting safety optic scan results from Slave units and the synchronization between them to avoid mutual interference.
  • Page 4: Alignment Procedure

    Switch OFF and ON the device in normal operating mode. To check alignment level for periodical maintenance ESPE must be restarted in Alignment Mode. For cascaded system start the alignment procedure always from Master unit, then proceed with Slaves. NOTE SLIM...
  • Page 5: Diagnostic Function

    ) and any cause of electrical inter- ference, then power cycle the ESPE Con- Check for proper connection (see " Power supply failure nections" on page 2 If failure persists after recommended checks and ESPE power cycle, please contact DATALOGIC. QUICK REFERENCE GUIDE...
  • Page 6 Cascade connection" on page " Failure on Restart function, check RESTART SELECTION F13: Failure on connection (see “Restart mode restart selection and Restart function” in Instruction Manual) If failure persists after recommended checks and ESPE power cycle, please contact DATALOGIC. SLIM...
  • Page 7 Since the directives and applicable standards are subject to continuous updates, and since Datalogic promptly adopts these updates, therefore the EU declaration of conformity is a living document. The EU declaration of conformity is available for competent authorities and customers through Datalogic commercial reference contacts.
  • Page 8 © 2019 Datalogic S.p.A. and/or its affiliates • All rights reserved • Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A.