Download Print this page

Inelco 2060 Operating Instructions Manual

Stationary fan heater 6-9-12-15kw

Advertisement

Quick Links

STATIONARY FAN HEATER 6-9-12-15kW
GB
Operating Instructions
General recommendations
Read these instructions before using the appliance. Keep these instructions
in a safe place for future reference.
First time of use
While the manufacturing of the heaters, oil, residues adhere to the ele-
ments. The first time of use, these residues will be burnt off, thereby occa-
sionally triggering fire alarms. Precautions should be taken in order to pre-
vent this from happening.
Area of use
The SH 6-15 kW fan heaters are not intended for use other than indoors.
These heaters are appropriate for the heating of warehouses, workshops,
storage rooms, show rooms, etc.
Function
The air is carried through the heater by a fan and heated by non-corrosive
elements which are regulated by the built-in thermostat with at range of +5
- +35°C. The air speed is adjustable in three steps. Switching on or off, se-
lecting half or full output and regulating the RPM is performed through the
control box CB2, which is wall mounted for easy access. The appliance is
protected from overheating via a built-in temperature limiter. To reset, see
Overheating. Te heater is mounted on a wall with a bracket, which allows
01-01-2017 RS
Type 2060/2090/2120/2150
51125015
51125015 X V1
1

Advertisement

loading

Summary of Contents for Inelco 2060

  • Page 1 Type 2060/2090/2120/2150 51125015 STATIONARY FAN HEATER 6-9-12-15kW Operating Instructions General recommendations Read these instructions before using the appliance. Keep these instructions in a safe place for future reference. First time of use While the manufacturing of the heaters, oil, residues adhere to the ele- ments.
  • Page 3: Electrical Installation

    Installation The fan heater is intended for wall mounting. The appliance must not be placed directly under a wall-outlet. The minimum distances given in fig. 1 and 2 must be kept. The fan heaters must not be mounted on the ceiling. ...
  • Page 4: Maintenance

    Maintenance The motor and other components are maintenance-free. Dust and dirt may cause overheating and danger of fire. The appliance must be cleaned regu- Mounting on wall – fig 1.
  • Page 5 Mounting on wall – fig 2. SH ° Measurements in mm SH6,SH9: A = 400 B = 460 C = 490 SH12,SH15: A = 450 B = 585 C = 560...
  • Page 6: Manufacturer's Declaration Of Conformity

    Manufacturer’s Declaration of Conformity We, the undersigned INELCO HEATERS A/S - Industrivej 3 - DK-9690 Fjerritslev certify that the product: Stationary Fan Heater Type Rating 2060 6kW - 3x400V - 50 Hz 2090 9kW - 3x400V - 50 Hz 2120...