SHIPPING, RIGGING, HOISTING AND ASSEMBLY MANUAL
ENERGY RECOVERY VENTILATORS
LE6X
LE8X
LE10X
RENEWAIRE.COM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LE6 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RenewAire LE6 Series

  • Page 1 SHIPPING, RIGGING, HOISTING AND ASSEMBLY MANUAL ENERGY RECOVERY VENTILATORS LE6X LE8X LE10X RENEWAIRE.COM...
  • Page 2 (additional charges apply). heater, verify that the air being extracted by the ERV does not See separate unit-specific Installation, Operation and conflict with proper operation of the fuel-burning device. Maintenance manual for further information. RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499...
  • Page 3: Unit Information

    IMPORTANT USER INFORMATION SAVE THIS MANUAL UNIT INFORMATION In the unlikely event that factory assistance is ever required, information located on the unit label will be needed. Configuration (Option) Code Unit Label (typical) 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM...
  • Page 4: Table Of Contents

    8.3 LE6XINVH CORNER WEIGHTS 9.0 LE8X CORNER WEIGHTS 9.1 LE8XRT CORNER WEIGHTS 9.2 LE8XINH CORNER WEIGHTS 9.3 LE8XINVH CORNER WEIGHTS 10.0 LE10X CORNER WEIGHTS 10.1 LE10XRT CORNER WEIGHTS 10.2 LE10XINH CORNER WEIGHTS 10.3 LE10XINVH CORNER WEIGHTS RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499...
  • Page 5 Wiring Harness Routing Access Panel Removal Wiring Harness Connections OA Hood Screw Locations EA Hood Screw Locations Access Panel Installation OA Hood Installation EA Hood Installation Filter Spacers Filter Racks Filter Extractor Hook 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM...
  • Page 6: Shipping

    If shipping damage is discovered, take digital pictures and note the visible damage on the ship- ping manifest. Notify your RenewAire dealer immediately. Note that whenever possible, accessories such as weather hoods are assembled and then secured for shipping inside the ERV.
  • Page 7: Rigging

    Do not lift in high winds. RenewAire will not be responsible for any damage during the rigging, lifting or installing of the unit or modules. Refer to Corner Weight Charts for exact center of gravity.
  • Page 8: Rigging Assembly Graphic 1

    RIGGING SHIPPING, RIGGING, LIFTING AND ASSEMBLY: LE MODELS Rigging Assembly Graphic 1 www.renewaire.com (800) 627- 4499 support@renewaire.com Rigging Assembly Graphic 2 www.renewaire.com (800) 627- 4499 support@renewaire.com www.renewaire.com Corner Lifting Lug (typ) (800) 627- 4499 support@renewaire.com RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
  • Page 9: Forklift Requirements

    4.0 MODULE ASSEMBLY 4.1 CONFIGURATION LABEL RenewAire LE series Energy Recovery Ventilators can either be built and shipped factory assembled or be ordered unassembled for applications where modules must be manipulated separately. If the unit was ordered unassembled, then you will need to assemble the modules in the field.
  • Page 10: Remove Shipping Straps

    Shipping straps are attached to the modules at the factory. These straps insure proper rigidity when shipping and lifting. Once the straps are removed they may be disposed of along with the screws that held them in place. www.renewaire.com (800) 627- 4499 Shipping Straps Location support@renewaire.com...
  • Page 11: Join Modules Together

    THEN 2 MORE BOLTS IN BASE ACCESS BOLT AND NUT SUPPORT. THROUGH HAND HOLES IN EACH MODULE SIDE BASE RAIL TO BE JOINED. 2 BOLTS THROUGH LIFTING LUGS (EACH SIDE OF UNIT) LE Rooftop Unit Base Bolt Locations 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM...
  • Page 12: Bolt Together Mating Roof Beams

    USE A PIPE CLAMP TO ADJUST THE ROOF BEAMS LATERALLY AND THEN BOLT TOGETHER THE TWO ROOF BEAMS. Roof Beam Assembly Graphic 2 Roof Beam Assembly Bolt Locations www.renewaire.com (800) 627- 4499 support@renewaire.com RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499...
  • Page 13: Caulk The Seams

    Roof Beam Caulking www.renewaire.com (800) 627- 4499 support@renewaire.com 4.5.4 Install Joining Roof Cap A galvanized cap roof flange is provided to seal the roof seam and to maintain a water and airtight seal.
  • Page 14: Install Assembly Straps

    For best results, use a lower torque setting on the power drill. Be careful not to over tighten the screw. Assembly Strap Locations Assembly Strap Installation www.renewaire.com (800) 627- 4499 support@renewaire.com NOTE: Failure to install the assembly straps will compromise the structural integrity of the unit and cause damage during lifting.
  • Page 15: Connect The Wiring Harness

    Inside the access panel are low voltage and high voltage wiring connection compartments. The low voltage compartment is the lower compartment and the high voltage compartment is the upper compartment. Both compartments are open on the left side to access the wiring harness plugs that are www.renewaire.com (800) 627- 4499 support@renewaire.com www.renewaire.com...
  • Page 16: Install Weatherhoods

    4.7 INSTALL WEATHERHOODS Rooftop units (RT models) have weatherhoods that are shipped loose and must be field-installed. Installation of the hoods is normally performed after all rigging and hoisting is completed because of www.renewaire.com (800) 627- 4499 support@renewaire.com the chance of damage to the hoods by the rigging equipment.
  • Page 17: Install Merv-8 Filters

    LE units ship with 20” X 25” X 2” (nominal) MERV-8 air filters. Filters are shipped loose in LE-RT units or may be installed prior to shipment in LE-IN units. In addition, RenewAire provides a set of filter spacers and a filter extractor hook, all shipped loose.
  • Page 18: Rooftop Curb Dimensions

    Swing 60 1/2" I.D. TOP VIEW Model: LE6X RTV/RTR AIRFLOW CONFIGURATION Drawing Type: Unit Dimension Available as shown: Version: MAY18 111" Minimum Service Area 13 3/8" X 15 1/2" RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499 Electrical TOP VIEW Connection...
  • Page 19: Le10Xrt Curbs

    HERT except 6x 8x, LERT Flange LEFT VIEW FRONT VIEW 165 3/8" Overall AIRFLOW CONFIGURATION Model: LE10X RTV/RTR 162 5/8" Case Available as shown: Drawing Type: Unit Dimension Version: MAY18 LE-SERIES OA Inlets, OA Damper 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM Locations (Optional)
  • Page 20: Rooftop Unit Dimensions

    HERTexcept 6x 8x, LERT FRONT VIEW Model: LE6X RTH/RTF AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION Drawing Type: Unit Dimension Available as shown: Must be mounted as shown. Airstreams can not RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499 be switched. Version: MAY18...
  • Page 21: Le8Xrth-F Dimension Drawing

    HERTexcept 6x 8x, LERT Flange Model: LE8X RTH/RTF AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION Drawing Type: Unit Dimension Available as shown: Must be mounted as shown. Airstreams can not be switched. Version: MAY18 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM...
  • Page 22: Le10Xrth-F Dimension Drawing

    Knockouts FRONT VIEW RIGHT VIEW AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION Model: LE10X RTH/RTF Available as shown: Must be mounted as shown. Airstreams can not Drawing Type: Unit Dimension be switched. RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499 Version: MAY18...
  • Page 23: Indoor Unit Dimensions

    AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION Model: LE6XINV 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM Available as shown in dimension drawing. Must be mounted as shown. RA/EA airstream can Drawing Type: Unit Dimension be switched with OA/FA airstream unless certain Version: MAY18 options are selected.
  • Page 24: Le8Xinh Dimension Drawing

    Model: LE8XINV Available as shown in dimension drawing. Must be mounted as shown. RA/EA airstream can Drawing Type: Unit Dimension be switched with OA/FA airstream unless certain Version: MAY18 options are selected. RENEWAIRE.COM INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1.800.627.4499 LE-SERIES...
  • Page 25: Le10Xinh Dimension Drawing

    UNIT MOUNTING & APPLICATION Drawing Type: Unit Dimension Available as shown in dimension drawing. Must be mounted as shown. RA/EA airstream can be switched with OA/FA airstream unless certain Version: MAY18 options are selected. 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM LE-SERIES...
  • Page 26: Le6X Corner Weights

    Do not scale drawing Sheet 1 of 4 "B" 5 HP 1024 LE-6X-RT Corner Weights 1/30/2014 MF SPECIFICATIONS SUBJECT RenewAire LLC LE-6X-RT_CORNER_WEIGHTS_MAY18.dwg 3 HP 1017 TO CHANGE WITHOUT NOTICE. Do not scale drawing Sheet 1 of 4 7.5 HP 1083 "A"...
  • Page 27: Le6Xinh Corner Weights

    Sheet 1 of 4 Do not scale drawing TO CHANGE WITHOUT NOTICE. Sheet 1 of 4 7.5 HP 1009 7.5 HP "A" RenewAire LLC LE-6X-INH_CORNER_WEIGHTS_MAY18.dwg RenewAire LLC LE-6X-INV_CORNER_WEIGHTS_MAY18.dwg ADDITIONAL WEIGHTS FOR OPTIONS (lbs.) ADDITIONAL WEIGHTS FOR OPTIONS (lbs.) Options UNIT...
  • Page 28: Le8X Corner Weights

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Do not scale drawing Sheet 1 of 4 BASIC UNIT WEIGHTS (lbs.) 73.5" Lifting Lug BASIC UNIT WEIGHTS (lbs.) 73.5" Lifting Lug RenewAire LLC LE-8XRT_CORNER_WEIGHTS_MAY18.dwg Motors UNIT Door End Door End Motors UNIT LE-8X-RT Corner Weights...
  • Page 29: Le8Xinh Corner Weights

    Sheet 1 of 4 Do not scale drawing TO CHANGE WITHOUT NOTICE. Sheet 1 of 4 "B" 7.5 HP 1280 7.5 HP RenewAire LLC LE-8X-INH_CORNER_WEIGHTS_MAY18.dwg RenewAire LLC LE-8X-INV_CORNER_WEIGHTS_MAY18.dwg ADDITIONAL WEIGHTS FOR OPTIONS (lbs.) ADDITIONAL WEIGHTS FOR OPTIONS (lbs.) "A" Options...
  • Page 30: Le10X Corner Weights

    SPECIFICATIONS SUBJECT BASIC UNIT WEIGHTS (lbs.) 73.5" Lifting Lug TO CHANGE WITHOUT NOTICE. Do not scale drawing Sheet 1 of 4 73.5" Lifting Lug BASIC UNIT WEIGHTS (lbs.) RenewAire LLC LE10X-RT_CORNER_WEIGHTS_MAY18.dwg Motors UNIT Door End Door End Motors UNIT LE10X-RT Corner Weights...
  • Page 31: Le10Xinh Corner Weights

    TO CHANGE WITHOUT NOTICE. Sheet 1 of 4 Do not scale drawing "B" Sheet 1 of 4 7.5 HP 1489 7.5 HP 1127 RenewAire LLC LE10X-INH_CORNER_WEIGHTS_MAY18.dwg RenewAire LLC LE10X-INV_CORNER_WEIGHTS_MAY18.dwg 10 HP 1508 10 HP 1127 "A" ADDITIONAL WEIGHTS FOR OPTIONS (lbs.) ADDITIONAL WEIGHTS FOR OPTIONS (lbs.)