GE AF-650 GP Operating Instructions Manual page 57

Opceip ethernet/ip
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Class ID 0x06 Connection Manager
Attribute
Access
1
Get
2
Get
3
Get
4
Get
5
Get
6
Get
7
Get
8
Get
9
Get
Table 8.3: Instance Attributes
Class ID 0x28 Motor Data Object
Attribute
Access
1
Get
2
Get
3
Get/Set
6
Get/Set
7
Get/Set
8
8
Get/Set
9
Get/Set
12
Get/Set
15
Get/Set
Table 8.4: Instance Attributes
NB!
Class ID 0x28 is only available if ODVA profile is selected in par. O-10 Control Word Profile.
Class ID 0x29 Control Supervisor Object
Attribute
Access
1
Get
2
Get
3
Get/Set
4
Get/Set
5
Get/Set
6
Get
7
Get
8
Get
9
Get
10
Get
11
Get
12
Get/Set
13
Get
15
Get
Table 8.5: Instance Attributes
56
Name
Open Requests
Open Format Rejects
Open Resource Rejects
Open Other Rejects
Close Requests
Close Format Requests
Close Other Requests
Connection Timeouts
Connection Entry List Struct of: NumCon-
nEntries
Name
Number of Attributes supported
List of attributes supported
Motor Type
Rated Current
Rated Voltage
Rated Power
Rated Frequency
Pole Count
Base Speed
Name
Number of Attributes supported
List of supported Attributes
Run 1 (forward)
Run 2 (reverse)
Network Control
State
Running 1
Running 2
Ready
Faulted
Warning
Fault reset
Fault Code
Control from net
Data Type
Description
UINT
Number of Forward Open requests received
UINT
Number of Forward Open requests rejected due to bad format
UINT
Number of Forward Open requests rejected due to lack of resources
UINT
Number of Forward Open requests rejected due to other reasons
UINT
Number of Forward Close requests received
UINT
Number of Forward Close requests rejected due to bad format
UINT
Number of Forward Close requests rejected due to other reasons
UINT
Number of connection timeouts
INT
Number of connection entries ConnOpenBits ARRAY of BOOL List of
connection data
Data Type
Parameter
USINT
-
Array of USINT
-
USINT
P-20
UINT
P-03
UINT
F-05
UDINT
P-07
UINT
F-04
UINT
P-01
UINT
P-06
Data Type
Description
USINT
12
Array of USINT
3,4,4,5,6,7,8,9,10,11,12,13,15
Boolean
Drive CTW Bit 6 = Run1 XOR Run2
Drive CTW Bit15 = 0
Boolean
Drive CTW Bit 6 = Run1 XOR Run2
Drive CTW Bit15 = 1
Boolean
Parameter EN-32 value written from option
USINT
The state of the CIP state-machine
Boolean
Run1 AND bit 11 in Drive STW
Boolean
Run2 AND bit 11 in Drive STW
Boolean
STATE_ENABLED or STATE_STOPPING or
STATE_FAULT_STOP from state-machine
Boolean
Bit 3 in Drive STW
Boolean
Bit 7 in Drive STW
Boolean
Bit 7 in Drive CTW
UINT
Mapping of par. DR-90 Alarm Word to CIP specific fault
codes
Boolean
Parameter EN-31 value written from option
OPCEIP EtherNet/IP
Description
7
3,6,7,8,9,12,15
3: PM sync. motor (AF-650 GP only)
7: Squirrel cage induction motor
Unit: 100 mA
Unit: Volt
Unit: Watt
Unit: Hertz
Number of poles in motor
Unit: RPM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Af-600 fp