7 Troubleshooting

7.1.1 Step-by-step Troubleshooting

Check: LEDs
The option contains two LEDs to indicate the state of the device and the network. During normal operation the MS and at least one NS LED will show a constant
green light.
State
Standby
Green:
Device operational
Green:
Major recoverable fault
Major unrecoverable fault Red:
Red:
Self test
Green:
Table 7.1: MS: Module Status
State
No connections
Green:
Connected
Green:
Connection time-out
Red:
Duplicate IP
Red:
Red:
Self test
Green
Table 7.2: NS1 + NS2: Network Status (one per port)
Check: Link Status
The status of the Ethernet link cannot be directly identified by means of the LEDs, if no CIP connection is established.
Use par. EN-10, Link Status to verify presents of the link.
Use par. EN-11, Link Duration to verify that the link is steady present.
The parameter will show the duration of the present link, and preset to 00:00:00:00 if the link is broken.
Check: Cabling
In rare cases of cabling mis-configuration, the option might show the presents of a link, but no communication is running. Exchange the cable in doubt.
Check: IP Address
Verify that the option has a valid IP address (please refer to section: IP Settings) in par. EN-01, IP Address. If the option has identified a duplicate IP Address NS
LEDs will light steady red. If the option is set up for BOOTP or DHCP, verify that a BOOTP or DHCP server is connected in par. EN-04, DHCP Server. If no server is
connected, the parameter will show: 000.000.000.000.

7.1.2 Alarm Word and Warning Word

Alarm word and warning word are shown in the display in Hex format. If there is more than one warning or alarm, a sum of all warnings or alarms will be shown.
Warning word and alarm word are displayed in par. DR-90 to DR-95. For more information on the individual alarms and warnings, please refer to: AF-650 GP/
AF-600 FP Design Guide.
NB!
Please note that the availability of the individual alarms and warnings are dependent on the drive type: AF-600 FP/AF-650 GP series.
Warning and Alarm Messages
There is a clear distinction between alarms and warnings. In the event of an alarm, the frequency converter will enter a fault condition. After the cause for the
alarm has been cleared, the master must acknowledge the alarm message in order to start operation of the frequency converter again. A warning, on the other
hand, may appear when a warning condition arises, then disappear when conditions return to normal without interfering with the process.
LED
Flashing green
The device needs commissioning
Solid green
The device is operational
Flashing red
The device has detected a recoverable fault (MAR)
Solid red
The device has detected a un-recoverable fault (MAU)
Flashing red/green The EIP option is in self-test mode
LED
Flashing green
There are no established any CIP connections to the device
Solid green
There is established (at least) one CIP connection to the
device
Flashing red
One or more CIP connections has timed-out
Solid red
The IP-address assigned to the device is already in use
Flashing red/green The EIP option is in self-test mode
OPCEIP EtherNet/IP
Description
Description
7
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Af-600 fp

Table of Contents