Toro TBC WP User's Manual And Installation Instructions page 5

Table of Contents

Advertisement

Connecting the Valve
The TBC
WP controller can only operate valves equipped with a DC Latching solenoid. Verify
TM
that the device being controlled is equipped with the proper solenoid.
Connecting the Valves
Step 1 –
If connecting more than one valve,
determine the station designation
for each valve. For programming
purposes, note the zone that each
valve/station will service.
Step 2 –
Connect the TBC
station 1 wire to the positive (red)
wire lead from Station 1 solenoid.
Connect the TBC
C (common) wire (black) to the
negative (black) solenoid wire.
Connect the remaining Station
wires (colored) to their respected
soleoid wires in the same manner.
NOTE:
proof wire connectors (not
supplied) for this application.
Step 3 –
Check the valve(s) and controller for proper operation. (Refer to TBC
Guide for operation.)
WP controller's
TM
WP controller's
TM
Use water sealed/
Station
Station 1
Station 2
Wire Color
1
Red
2
Orange
3
Gray
4
Green
5
Blue
6
Brown
Station 3