PNOZ s1
Safety features
The relay meets the following safety requirements:
The circuit is redundant with built-in self-monitoring.
}
The safety function remains effective in the case of a component failure.
}
The correct opening and closing of the safety function relays is tested automatically in
}
each on-off cycle.
The unit has an electronic fuse.
}
Block diagram/terminal configuration
A1 A2
=
=
Power
Centre: Front view with cover, right: Front view without cover
Function description
Single-channel operation: no redundancy in the input circuit, earth faults in the reset
}
and input circuit are detected.
Automatic start: Unit is active once the input circuit has been closed.
}
Manual reset: Unit is active once the input circuit is closed and then the reset circuit is
}
closed.
Increase in the number of available instantaneous safety contacts by connecting con-
}
tact expander modules or external contactors/relays;
A connector can be used to connect 1 PNOZsigma contact expander module.
Operating Manual PNOZ s1
21393-EN-07
13 23
Input
K1
K2
Reset/
Start
Y32
S34
14
24