Order Reference; Ec Declaration Of Conformity - Pilz PNOZ s1 Operating Manual

Safety relays
Hide thumbs Also See for PNOZ s1:
Table of Contents

Advertisement

PNOZ s1
Safety characteristic data
Operating
EN ISO
mode
13849-1:
2006
PL
Safety con-
PL c
tacts, instan-
taneous
All the units used within a safety function must be considered when calculating the safety
characteristic data.

Order reference

Order reference
Product type Features
PNOZ s1
PNOZ s1 C

EC declaration of conformity

This product/these products meet the requirements of the directive 2006/42/EC for machin-
ery of the European Parliament and of the Council. The complete EC Declaration of Con-
formity is available on the Internet at www.pilz.com/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfil-
dern, Germany
Operating Manual PNOZ s1
21393-EN-07
EN ISO
EN IEC
13849-1:
62061
2006
SIL CL
Category
Cat. 3
SIL CL 2
Information
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
24 V DC
24 V DC
IEC 61511
EN IEC
62061
SIL
PFH
[1/h]
D
2,00E-07
SIL 2
Terminals
Screw terminals
Spring-loaded terminals 751 101
IEC 61511
EN ISO
13849-1:
PFD
2006
T
[year]
M
5,95E-03
20
Order
no.
750 101
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

750101751101