User's Guide
Relax Comfort Duo requires a 230V, 1x10A (2 kW, standard) or 1x16A (3 kW) connection, 
via a main breaker switch. A residual current device must be engaged. It is also 
recommended that a timer (clock) with an on/off switch be installed to ensure that the 
filtration systems runs about 4‐6 hours per day. E.g. 2 x 2 hours, or 2 x 3 hours, depending 
on what is most appropriate for the user. Meanwhile, the electrical heater also turns on if 
the temperature drops below the set value.  
WARNING! 
A. The electrical installation should only be done by qualified persons. 
B. Read instructions carefully before installation begins.  
C. We are not responsible for product malfunction or damage if the instructions are not followed 
during installation.  
D. Make sure that the product is not damaged in transit during unpacking. 
E. Do not connect power before the installation is complete. 
F. NOTE! If the hot tub is built into a terrace or similar, the construction shall be built in such a way 
that all sides are freely accessible for servicing. Outer paneling and eventual insulation must be 
easily removable. 
G. Read the technical instructions before installing the bath  
H. Read the users instructions before using the bath  
I. Do not leave children in the bath without supervision  
J. Do not sit with your back or head against the skimmer 
K. If automatic dispensers (floating, etc.) are used, careful adjustment should be made to avoid 
incorrect dosage. Follow the recommendations in our instructions. 
L. The circulation pump also generates heat and if it is running a long time it can raise the 
temperature by several degrees in one day when the tub is well insulated.  
M. Check the quality of the water, as well as temperature and function, regularly, don't leave the spa 
unmonitored for long time periods.
N. If the water's drained and the bath isn't in use during cold weather, then all screw connections 
are to be left open so that any water can drain out. 
O. When filling water and the temperature is below freezing, the pumps and pipes are also cold. 
Take this into account and fill with warm water first, or warm up the space with an appropriate 
heater before filling with water. 
P. A frost guard can be placed in the technical area to protect against damage from freezing in cold 
weather if the equipment fails. 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RelaxComfortDuo and is the answer not in the manual?

Questions and answers

Summary of Contents for SpaDealers RelaxComfortDuo

  • Page 1 2019-08-16   Relax Comfort Duo   User’s Guide Relax Comfort Duo requires a 230V, 1x10A (2 kW, standard) or 1x16A (3 kW) connection,  via a main breaker switch. A residual current device must be engaged. It is also  recommended that a timer (clock) with an on/off switch be installed to ensure that the  filtration systems runs about 4‐6 hours per day. E.g. 2 x 2 hours, or 2 x 3 hours, depending  on what is most appropriate for the user. Meanwhile, the electrical heater also turns on if  the temperature drops below the set value.   WARNING!  A. The electrical installation should only be done by qualified persons.  B. Read instructions carefully before installation begins.   C. We are not responsible for product malfunction or damage if the instructions are not followed  during installation.   D. Make sure that the product is not damaged in transit during unpacking.  E. Do not connect power before the installation is complete.  F. NOTE! If the hot tub is built into a terrace or similar, the construction shall be built in such a way  that all sides are freely accessible for servicing. Outer paneling and eventual insulation must be  easily removable.  G. Read the technical instructions before installing the bath   H. Read the users instructions before using the bath   I. Do not leave children in the bath without supervision   J. Do not sit with your back or head against the skimmer  K. If automatic dispensers (floating, etc.) are used, careful adjustment should be made to avoid  incorrect dosage. Follow the recommendations in our instructions.  L. The circulation pump also generates heat and if it is running a long time it can raise the  temperature by several degrees in one day when the tub is well insulated.  ...
  • Page 2 Startup At startup    1. Fill water to the level  (Max / Min) shown on the  skimmer. See the last  page.    2. Open both valves (A &  B) to the filter.    3. Open the air screw (C)  on top of the filter and  close when water comes  out.    4. Start.    Draining is done via a  special drain valve (E)  next to the filter.    The desired temperature  is set on the graduated  thermostat dial. The  pump must be running for  the heater to operate.     Button to start and stop  are found on the left side  next to the service door.    The electricity is  connected via the  junction box (D).    230V / 10A (2 kW) or 16A  (3 kW) fuse required. ...
  • Page 3 Maintenance instructions     Thank you for choosing a SpaDealers Hot Tub. We try to do our utmost to  ensure that you will be satisfied with our products. If you have any queries,  please contact us at +358‐(0)10‐239 5600 or info@spadealers.fi     Foundation and placement options      Nur m i Puual us t a Ki vi - t ai val ul aat t a Gr äs Tr äs t om m e St en- el l er gj ut en pl at t a...
  • Page 4 Recommended water level  HIGHER WATER LEVELS RESULT LESS             SUCTION SURFACE WATER VICE             VERSA     Cleaning of filters      Cleaning the filter cartridge: In addition to washing the filter with eg. a hand held shower, you also need  to clean the filter cartridge "in depth". Minerals and other contaminants that are very difficult to detect  can get stuck deep inside the filter's fibers, thus causing problems with the water flow.    Filter cleaning:  1. Put the dirty filter in a bucket of water and add machine washing detergent or Filter Cleaner.  2. Leave it submersed in the sink for at least 12 hours.  3. Remove the filter and rinse it clean. with a water hose or hand held shower, both inside and out.   Let it dry properly before reinstalling.  Unscrew the air screw on top of the filter.

Table of Contents