BULLETIN No.SHB-0810-3CE OWNER’S (OPERATOR’S) MANUAL AND SAFETY INSTRUCTION KITO SHORT HEADROOM TYPE < MANUAL CHAIN HOIST > WARNING This owner’s (operator’s) manual and safety instruction describes special steps to ! be taken with the Short Headroom Type Chain Hoist. Prior to use , make sure to read both the “Short Headroom type”...
Page 2
2. SPECIFICATIONS Code Std. Chain pull to lift Net weight Lift full load (kg) SHB005 SHB010 SHB020 SHB030 SHB050 SHB075 SHB100 3. INSTALLATION WARNING ! Always make sure on mounting that the chain is properly engaged with the idle sheave and is free of twisting, slack, etc. ADJUSTING BEAM WIDTH ●...
Page 3
MOUNTING TROLLEY ON RAIL There are two ways for mounting the trolley on the travelling rail in accordance with location of the travelling rail installation in the building. 1) Mounting from the rail end After setting to the appropriate beam width of the trolley, remove the rail end stopper and mount the assembled trolley from the rail end as in the following drawing.
Page 4
MOUNTING STOPPER Always make sure to mount the stopper to prevent dropping of the trolley at the rail end. Fabricate the stopper based on the following table and drawing, and determine the position for its’ mounting according to wheel size, RAIL WIDTH MATERIAL SIZE E Q’ty BOLT, NUT...
Page 5
MOUNTING CHAIN CONTAINER (OPTIONAL) Mount the chain container according to the following procedure. (See the drawing below:) 1) Fix the container sling fitting to the chain container by using the container sling fitting bolt B. 2) Fix the chain container assembly to the frame by using the container sling fitting bolt A and collar.
Page 6
SAFETY INSTRUCTIONS PRE-START INSPECTION WARNING Daily inspection is a MUST for safety purposes. Always perform a daily ! inspection before starting operation. ―― Checking Items ―― Check before opening Does the unloaded trolley travel smoothly without any load? Is travel free of jolts? ...
Page 7
WARNING ! ● Always refer to the “Standard CB Series Manual Chain Hoist” instruction manual for pre-start inspection procedures for the hoisting unit. Never use a hoist under abnormal condition. Always stop operation immediately on detection of any abnormality, and either repair or replace the damaged part with the appropriate product without delay.