Electrical Connection; Heating Operation - Dimplex IRP 300W Installation And Operating Instructions Manual

Infra-red heating structure
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
English
Wall mounting
ATTENTION!
Do not install the device directly below a wall
socket.
Installation on wooden walls is permissible.
The heating device must be installed on a vertical wall
(see illustration). The minimum clearances must be
observed. In addition, a clearance of 500 mm is to be
maintained in front of the unit. All dimensions in mm.
Mark and drill the mounting holes for the bracket
and insert the dowels.
Screw bracket tight.
Mount heating device into bracket.
Ceiling mounting
The heating device must be installed on a horizontal
ceiling (see illustration).
If suspension from the ceiling is necessary, the "IRP
cable set" accessory must be used.
EN-3

3. Electrical connection

The voltage specified on the type plate must match
the line voltage.
It is recommended that a separate electric circuit be
provided for the power supply.
The heating device is designed for fixed connection to
a wall socket. When mounting on a wall, route the de-
vice connection cable downwards.
The device must only be installed and repaired by a
qualified electrician in accordance with the applicable
safety regulations.
Connection may only take place on securely routed
cables!
A disconnecting device with a contact opening of at
least 3 mm at each pole (e.g. circuit breaker) must be
provided in the permanently installed wiring.

4. Heating operation

NOTE
Only use the device for room heating within enclosed
rooms.
The heating device may only be
operated in conjunction with an external room ther-
mostat with the following functions:
electronically controlled week programme,
adaptive control of the heating start,
further energy-saving functions.
Please observe the operating instructions for the
room thermostat.
Recommended room thermostat: Dimplex DTB 2R
5.
Faults
If the heating device is not emitting any heat, check
the temperature setting on the room thermostat, then
check whether the fuse in the electricity distribution is
switched on.
For your safety, the heating device is equipped with
an integrated overload protector. The device switches
off automatically in the case of impermissible heating
of the heating device (e.g. due to it being hung or po-
sitioned incorrectly).
Before recommissioning, remove the causes behind
the overload protector being triggered.
Once the device has cooled down sufficiently, the
overload protector switches off again automatically
and the device can be operated again.
If you cannot correct the fault, please contact a spe-
cialist electrical service centre or else the service cen-
tre for Dimplex devices. Please have the E-number
printed on the type plate ready.
2001/A
IRP – Infra-red heating
www.dimplex.de/en