NELSON
™
AXPTC125 POWER TEE SPLICE CONNECTION KIT
Pull excess heating cable back
through standoff.
STEP 3
Carefully slide enclosure adapter over cable
terminations.
Screw enclosure adapter into standoff until
fully seated at positive stop.
STEP 5
TULSA, OK 74146
GA-5052 Rev. 3
Sheet 6 of 10
August 2017
FINAL ASSEMBLY
Enclosure
Adapter
TEL 918-627-5530
Allow 1 ½" (3.81 cm) of each heating cable
to remain above top of standoff body.
STEP 4
Cable Tie
Mount standoff securely to pipe.
Insert supplied cable tie through slot
provided to prevent possible rotation of
enclosure.
STEP 6
FAX 918-641-7336
www.nelsonheaters.com
INSTALLATION
INSTRUCTIONS
1 ½" (38 mm)
Note: For pipes 1" (25mm)
and below, install HC_SPA
(purchased separately)
between standoff and pipe.
HC-SPA adapter
for small pipes.