Emerson NELSON AXPTC125 Installation Instructions Manual page 2

Power tee splice connection kit

Advertisement

NELSON
AXPTC125 POWER TEE SPLICE CONNECTION KIT
18" (46 cm)
 Mark pipe where standoff will be mounted.
 Allow approximately 18" (46 cm) of each heating cable
for installation.
 Heating cable may be cut at a 45° angle for easier
penetration.
LT / UT-1 SELF-REGULATING CABLE HLT / QLT / XLT SELF-REGULATING CABLE CLT SELF-REGULATING CABLE
Core
Bonded
Dielectric
Bus Wire
Jacket
TULSA, OK 74146
GA-5052 Rev. 3
Sheet 2 of 10
August 2017
STANDOFF POSITIONING
18" (46 cm)
18" (46 cm)
STEP 1
CABLE CONSTRUCTION DETAILS
Outer
Jacket
Core
Braid
Inner
Jacket
Bus Wire
TEL 918-627-5530
12" (31 cm)
 Insert cable retainer assembled with cable grommet into
standoff and clip into place.
 Insert heating cables through standoff allowing
approximately 12" (31 cm) of cable for terminations.
 Use cable lubricant if necessary.
 Proceed to Heating Cable Terminations.
Outer
Jacket
Core
Tinned
Copper Braid
Inner
Jacket
Bus Wire
FAX 918-641-7336
INSTALLATION
INSTRUCTIONS
STEP 2
Bare Copper
Braid
Inner
Jacket
www.nelsonheaters.com
Outer
Jacket