Operation

5

Adjustment of the separators

5.1
After installation, the separators described in this product infor-
mation manual are immediately ready for operation. An adjust-
ment is not required.
5.2

Adjustment of the sensor

A VEGA sensor powered via the VEGATRENN 149AEx can be
also adjusted via the VEGATRENN 149AEx. You will need a
Windows-PC with the configuration software PACTware™ and
a suitable instrument driver (DTM) according to the FDT stand-
ard. For connection, the VEGACONNECT 3 interface converter
with corresponding cable is required.
1
Fig. 10: Adjustment of the sensor via VEGACONNECT 3 and VEGATRENN
149AEx
1
Sensor
2
VEGATRENN 149AEx
Indication
3
4
HART adapter cable for VEGACONNECT 3
RS232 connection
5
6
PLC/Control system/Processing system
Necessary components:
Sensor
l
PC with PACTware™ and suitable VEGA DTM
l
VEGACONNECT 3 with HART adapter cable
l
VEGATRENN 149AEx
l
Separating and protective instruments – Separating and protective instruments
2
2
3
6
4 ... 20 mA
SPS
4
TM
PACTware
/
VEGA-DTM
5
VEGACONNECT 3