DIMENSIONS

INSTALLATION INSTRUCTIONS

Location
The pump should be located as close to the water as practicable and mounted on a firm base in
a well-drained position, high enough to prevent any flooding. It is the installer's/owners
responsibility to locate the pump so that it can be accessed for service and maintenance. The
rear fan shroud should be installed at a minimum distance of 100 mm away from any walls or
obstructions. This is to allow adequate air flow from the fan to cool the motor. Overheating due
to a lack of cooling voids warranty.

WEATHER PROTECTION

It is recommended that the pump be protected from the weather.
Enclosures should be ventilated to allow a free flow of air for the fan cooled motor.

POWER CONNECTION

OASIS pool and spa pumps are suitable for connection to a nominal 240-volt 50Hz power supply.
The motor is equipped with a flex and 3-pin plug. If a power outlet is not available within 2 meters of
the pump, a 3-pin power point in a safe, dry place may need to be provided by an electrician.
Note:
Pumps must be either
o Supplied by an isolating transformer, or
Supplied through a residual current device (RCD) with a rated residual operating current
o
not exceeding
Extension cords are unsafe around pools and must be avoided.
If the supply cord of this product is damaged the dealer or manufacturer must replace it,
with genuine OASIS pool and spa pump spares.
Water temperature is not to exceed 45 degrees
P SERIES HIGH PERFORMANCE - P270 | P330 | P380 | P490 POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
670
V390
@
700
30mA.
info@oasisaquatics.com.au
oasisaquatics.com.au