Troubleshooting - YASKAWA SI-232/J Technical Manual

Ac drive-j1000 option rs-232c interface
Table of Contents

Advertisement

7 Troubleshooting

7 Troubleshooting
Problems with the option interface may trigger an operator error.
Refer to the J1000 Technical Manual for all other errors.
Fault
LED Operator
Display
Cause
LED operator is
not properly
connected to the
drive or cables are
damaged
20
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
oPr
Digital operator connection fault
• Check the connection between the LED
operator and the drive
• Replace the cable if damaged
• Turn off the drive input power and
disconnect the LED operator
• Next reconnect the operator and turn the
drive input power back on
Fault Name
Possible solution