Download Print this page

Siemens GAMMA wave GE 561/01 Technical Product Information page 3

Switch actuator

Advertisement

Switch actuator wave GE 561/01
Connect power supply and load circuit (Diagram C)
-
The connections for the power supply and the load
circuits are composed of screw terminals (C1).
-
Insulate the conductors to be connected approx.
7 ... 8 mm, place in the terminals (C1) and screw in.
-
The lead sheath is to be attached with the wire fixing
(C2) to the housing of the installation device.
Note: Conductors up to 1.5 mm
looped directly to the terminal. It should be noted with
looping that the maximum terminal current of 16 A must
not be exceeded!
With installation it should be noted that the outer conduc-
tor (L) and the neutral conductor (N) must not be trans-
posed, since otherwise the sensitivity of the radio re-
ceiver will be reduced and telegram losses may thereby
occur.
C3
C4
Diagram C
C1
Screw terminals
C2
Wire fixing
C3
Pushbutton
C4
LED
Diagram D
Terminal assignment (Diagram D)
1 ––► Load output channel A
2 L1
Power supply (L) for actuator electronics and
channel A
3 N
Power supply (N) for actuator electronics
4 L2
Power supply (L) for channel B
5 ––► Load output channel B
Siemens AG
Automation and Drives Group
Electrical Installation Technology
P.O. Box 10 09 53, D-93009 Regensburg
2
single-wire can be
C1
C2
Kanal 1
1
L 1
2
N
3
L 2
4
Kanal 2
5
1
2 L1
3 N
4 L2
5
wave GE 561/01, 6 pages
© Siemens AG 2007
Subject to change without prior notice
Technical Product Information
Note: An outer conductor must always be connected to
terminal 2 (L1) even if channel A is not used, since the
actuator electronics are supplied with current via termi-
nals 2 and 3.
E1
E3
A
B
E2
E4
Diagram E
Connection example
E1
Switch actuator wave GE 561/01
E2
Actuator electronics
E3
Switch channel A
E4
Switch channel B
E5
Power supply AC 230V, 50 Hz
E6
Electric loads (e.g., lights)
Location and Function of the Display and Operating
Elements
Diagram C
C3
Pushbutton to switch over to the "special function"
operating mode, to select the commissioning func-
tions and to connect the switch actuator via radio.
C4
LED to display different settings and conditions in
the "special function" operating mode during com-
missioning.
Dimension Diagram
Dimensions in mm
32
42
GAMMA wave
February 2007
5WG3 561-4AB01
E5
L1 L2 N
1
2 L1
3 N
E6
4 L2
5
mounting holes 249 - 251
274,5
Technical Manual
Update: http://www.siemens.de/gamma
2.20.8.1/3