TECHNICAL DATA

DIMENSIONS
Height to hotplate
Space for fixing at hotplate level
Space for fixing above hotplate level
Minimum space above hotplate
Weight of appliance
Minimum distance from rear wall
CONNECTIONS
Gas
Electric
GRILL
Heat Input
Injector Marking
HOTPLATE
Heat Input
Injector Marking
Heat Input
Injector Marking
Height
900mm (nominal)
2mm minimum clearance
Flush-see important note 'Location of Appliance'.
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
67.0kg.
5mm (spacer given by pressed spacer on vent panel).
Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
230V-240V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 3 amp fuse.
Natural Gas
2.7kW (9215 Btu/h)
121
R.H.F.
1.0kW
(3412 Btu/h)
(6483 Btu/h)
070
R.H.F.
1.0kW
(71.85 g/h)
(136.5 g/h)
050
42
Width
600mm (nominal)
L.P.Gas
2.45kW (176 g/h)
078
Natural Gas
R.H.R.
L.H.R.
1.9kW
1.9kW
(6483 Btu/h)
096
096
L.P.Gas
R.H.R.
L.H.R.
1.9kW
1.9kW
(136.5 g/h)
071
071
Depth
600mm
(to front of
door panel)
L.H.F
2.9kW
(9895 Btu/h)
119
L.H.F.
2.9kW
(208 g/h)
083

Advertisement

Table of Contents
loading

Table of Contents