York YMA024 Technical Manual page 13

Affinity r-22 split-system heat pumps
Hide thumbs Also See for YMA024:
Table of Contents

Advertisement

COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
ID CFM
CONDENSER
ENTERING AIR
ID DB (°F)
TEMPERATURE
ID WB (°F)
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
Coil
F2RP/F2FP/F3FP036
F2FP/F3FP040
F2RP/F2FP/F3FP042
N1VSB12
G2FD036(S,H)17(T)
N1VSC16
G2FD036(S,H)21(T)
N1AHB08
G2FD036(S,H)17(T)
N1AHB12
G2FD036(S,H)17(T)
N1AHC16
G2FD036(S,H)21(T)
G1FA036S14(T)
G1FA036S17,21(T)
G2FD036(S,H)17(T)
G2FD036(S,H)21(T)
G1NA036S17J
G1NA036S21C
G1HD036
G1HA036H14(T)
G1HA036H17(T)
Unitary Products Group
YMA03611
G2FD036S17
1000
80
80
75
57
62
62
T.C.
34.8
38.3
37.7
S.C.
36.0
33.5
28.1
K.W.
2.4
2.4
2.4
T.C.
32.8
35.6
34.7
S.C.
34.0
32.2
26.6
K.W.
2.6
2.7
2.7
T.C.
30.8
32.9
31.7
S.C.
31.9
30.8
25.1
K.W.
2.9
2.9
2.9
T.C.
28.9
30.2
28.8
S.C.
29.9
29.5
23.7
K.W.
3.1
3.1
3.1
T.C.
27.2
28.2
26.3
S.C.
28.0
27.9
22.6
K.W.
3.3
3.3
3.3
T.C.
25.6
26.2
24.0
S.C.
26.2
26.2
21.6
K.W.
3.6
3.6
3.5
T.C.
24.0
24.2
21.6
S.C.
24.5
24.6
20.6
K.W.
3.8
3.8
3.8
T.C. S.C. KW
1.02
0.99
1.02
1.00
1.02
1.00
1.01
0.99
1.03
1.01
1.00
1.00
1.00
1.00
1.03
1.03
0.99
0.99
0.98
0.99
1.00
1.00
1.01
1.03
1.00
0.98
1.00
0.98
1.01
1.01
1.01
1.00
1.02
1.01
1200
80
80
80
80
75
67
72
57
62
62
41.6
40.7
37.8
39.6
39.0
27.7
20.1
38.5
36.5
30.3
2.5
2.5
2.5
2.5
2.5
39.1
39.3
35.5
37.0
35.9
26.7
19.6
36.2
35.0
29.0
2.7
2.7
2.7
2.7
2.7
36.6
38.0
33.3
34.4
32.8
25.7
19.1
33.9
33.4
27.6
2.9
3.0
2.9
2.9
2.9
34.2
36.7
31.0
31.9
29.6
24.7
18.7
31.5
31.9
26.3
3.2
3.3
3.1
3.1
3.1
31.4
33.5
29.1
29.6
27.1
23.6
17.6
29.4
29.8
24.9
3.4
3.5
3.4
3.4
3.3
28.8
30.4
27.2
27.4
24.7
22.6
16.6
27.3
27.8
23.6
3.6
3.8
3.6
3.6
3.6
26.1
27.4
25.3
25.2
22.2
21.5
15.6
25.2
25.8
22.3
3.9
4.0
3.9
3.9
3.8
Variable Speed
Furnace
1.00
P*DUA12V
1.00
P*DUB16V
1.00
P*DUB16V
0.95
P*DUC20V
0.93
P*DUC20V
1.00
P1XUB12V
1.00
P1XUB12V
1.01
P1XUC16V
1.00
P1XUC16V
0.99
P1XUC20V
1.00
P1XUC20V
0.99
P1XDB12V
1.00
P1XDB12V
1.00
P1XDC20V
1.00
0.99
0.99
036-21570-002 Rev. D (0605)
1400
80
80
80
80
75
67
57
62
62
67
42.0
40.2
40.8
40.9
40.4
29.5
20.6
40.9
39.5
32.6
2.5
2.5
2.5
2.5
2.5
39.7
39.2
38.2
38.4
37.1
28.7
20.4
38.4
37.8
31.4
2.7
2.7
2.7
2.7
2.7
37.5
38.2
35.7
35.9
33.8
28.0
20.1
35.8
36.0
30.1
2.9
3.0
2.9
2.9
2.9
35.2
37.1
33.1
33.5
30.4
27.2
19.9
33.2
34.3
28.9
3.2
3.3
3.1
3.2
3.1
32.3
33.8
30.9
31.0
27.9
26.0
18.8
31.0
31.8
27.2
3.4
3.5
3.4
3.4
3.4
29.5
30.7
28.8
28.6
25.4
24.8
17.7
28.9
29.4
25.6
3.7
3.8
3.7
3.7
3.6
26.7
27.5
26.7
26.2
22.8
23.7
16.7
26.8
27.0
24.0
3.9
4.0
3.9
3.9
3.8
T.C.
Coil
G1FA036S14(T)
0.99
G1FA036S17(T)
0.99
G2FD036(S,H)17(T)
1.01
G1FA036S21(T)
1.00
G2FD036(S,H)21(T)
1.03
G1FA036S17(T)
0.99
G2FD036(S,H)17(T)
1.01
G1FA036S21(T)
0.99
G2FD036(S,H)21(T)
1.03
G1FA036S21(T)
0.99
G2FD036(S,H)21(T)
1.03
G2FD036(S,H)17(T)
1.01
G1HA036H17(T)
1.03
G2FD036(S,H)21(T)
1.03
80
80
72
57
42.5
39.8
31.4
21.2
2.5
2.5
40.4
39.1
30.8
21.2
2.7
2.7
38.3
38.3
30.2
21.1
3.0
3.0
36.2
37.6
29.7
21.0
3.2
3.3
33.2
34.2
28.4
19.9
3.5
3.6
30.3
30.9
27.1
18.9
3.7
3.8
27.3
27.6
25.8
17.8
3.9
4.1
S.C.
KW
0.99
0.97
1.00
0.94
1.01
0.95
1.00
0.94
1.04
0.93
0.99
0.96
1.01
0.97
1.00
0.94
1.04
0.94
1.00
0.94
1.04
0.93
1.01
0.98
1.01
0.99
1.05
0.96
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yma02411Yma03011Yma03611Yma04211Yma04811Yma06011

Table of Contents