246646-YTG-C-0606
TABLE 16: ELECTRICAL DATA DH120 (10 TON) HIGH EFFICIENCY W/O PWRD CONVENIENCE OUTLET
OD Fan
Compressors
Motors
Voltage
RLA
LRA
FLA
ea.
ea.
ea.
208
16.0
137.0
3.5
230
16.0
137.0
3.5
460
8.3
69.0
1.6
575
6.4
58.0
1.3
*
Maximum HACR breaker of the same AMP size is applicable.
TABLE 17: ELECTRICAL DATA DH120 (10 TON) HIGH EFFICIENCY WITH PWRD CONVENIENCE OUTLET
OD Fan
Compressors
Motors
Voltage
RLA
LRA
FLA
ea.
ea.
ea.
208
16.0
137.0
3.5
230
16.0
137.0
3.5
460
8.3
69.0
1.6
575
6.4
58.0
1.3
*
Maximum HACR breaker of the same AMP size is applicable.
Unitary Products Group
Supply
Pwr
Pwr
Blower
Exh
Conv
Electric Heater
Motor FLA
Motor
Outlet
Model No.
2
3
FLA
FLA
HP
HP
None
2TP04521825
8.2
10.9
5.5
0.0
2TP04522425
2TP04523625
2TP04525425
None
2TP04521825
8.2
10.9
5.5
0.0
2TP04522425
2TP04523625
2TP04525425
None
2TP04521846
4.1
5.3
2.2
0.0
2TP04522446
2TP04523646
2TP04525446
None
2TP04521858
3.6
4.1
1.8
0.0
2TP04522458
2TP04523658
2TP04525458
Supply
Pwr
Pwr
Blower
Exh
Conv
Electric Heater
Motor FLA
Motor
Outlet
Model No.
2
3
FLA
FLA
HP
HP
None
2TP04521825
8.2
10.9
5.5
10.0
2TP04522425
2TP04523625
2TP04525425
None
2TP04521825
8.2
10.9
5.5
10.0
2TP04522425
2TP04523625
2TP04525425
None
2TP04521846
4.1
5.3
2.2
5.0
2TP04522446
2TP04523646
2TP04525446
None
2TP04521858
3.6
4.1
1.8
4.0
2TP04522458
2TP04523658
2TP04525458
Min. Circuit
Ampacity
Actual
Heater
(Amps)
KW
Amps
2
3
HP
HP
HP
--
--
51.2
53.9
56.7
13.5
37.5
57.1
60.5
64.0
18
50.0
72.7
76.1
79.6
25.5
70.8
98.7
102.1 105.6 109.0 100 110
40.6
112.7
151.1
154.5 158.0 161.4 175 175
--
--
51.2
53.9
56.7
18
43.3
64.4
67.8
71.3
24
57.7
82.4
85.8
89.3
34
81.8
112.5
115.9 119.4 122.7 125 125
54
129.9
140.2
143.5 147.0 150.4 150 175
--
--
26
27.2
28.2
18
22.6
32.2
33.7
34.9
24
30.1
41.2
42.7
34
42.7
56.2
57.7
54
67.8
70.1
71.6
72.8
--
--
20.6
21.1
22.4
18
18.1
26.2
26.8
28.4
24
24.1
33.4
34
35.6
34
34.1
45.4
46
47.6
54
54.2
56.5
57.1
58.7
Min. Circuit
Ampacity
Actual
Heater
(Amps)
KW
Amps
2
3
HP
HP
HP
--
--
61.2
63.9
66.7
13.5
37.5
69.6
73.0
76.5
18
50.0
85.2
88.6
92.1
25.5
70.8
111.2
114.6 118.1 121.5 125 125
40.6
112.7
163.6
167.0 170.5 173.9 175 175
--
--
61.2
63.9
66.7
18
43.3
76.9
80.3
83.8
24
57.7
94.9
98.3
101.8 105.2 100 100
34
81.8
125.0
128.4 131.9 135.2 125 150
54
129.9
152.7
156.0 159.5 162.9 175 175
--
--
31
32.2
33.2
18
22.6
38.4
39.9
41.2
24
30.1
47.5
49
50.2
34
42.7
62.5
64
65.2
54
67.8
76.3
77.8
79.1
--
--
24.6
25.1
26.4
18
18.1
31.2
31.8
33.4
24
24.1
38.4
39
40.6
34
34.1
50.4
51
52.6
54
54.2
61.5
62.1
63.7
MCA
Max
Max Fuse* Size
w/Power
Fuse*
w/Power
Exhaust
Size
Exhaust
(Amps)
(Amps)
(Amps)
2
3
2
3
2
HP
HP
HP
HP
59.4
60
60
70
67.3
60
70
70
83.0
80
80
80
110
110
175
175
59.4
60
60
70
74.6
70
70
80
92.7
90
90
90
100
125
125
175
175
29.4
30
35
35
36.4
35
35
35
44
45.5
45
45
45
59
60.5
60
60
60
74.3
80
80
80
22.9
25
25
25
29
30
30
30
36.2
35
35
40
48.3
50
50
50
59.3
70
70
70
MCA
Max
Max Fuse* Size
w/Power
Fuse*
w/Power
Exhaust
Size
Exhaust
(Amps)
(Amps)
(Amps)
2
3
2
3
2
HP
HP
HP
HP
HP
69.4
70
70
80
79.8
70
80
80
95.5
90
90
100
100
125
125
175
175
69.4
70
70
80
87.1
80
90
90
110
110
150
150
175
175
34.4
35
40
40
42.7
40
40
45
51.7
50
50
60
66.7
70
70
70
80.6
90
90
90
26.9
30
30
30
34
35
35
35
41.2
40
40
45
53.3
60
60
60
64.3
70
70
70
3
HP
70
70
90
70
80
35
40
50
70
80
25
30
40
50
70
3
80
80
80
90
40
45
60
70
90
30
35
45
60
70
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents