NOTE: These figures are indicative only. Ensure you check the total rating
of the appliance to be used before connecting to the generator. Refer to
page 23.
Always connect the largest appliance you want to run first allowing it
time to draw current to start . After 20-30 seconds connect the second
appliance.
NOTE: Ensure to reduce load when connecting appliances to the
generator by using smaller rated appliances or reducing the number of
appliances in use.

Preparation Information

Indicators
This generator has three main LED indicators to indicate to the operator
various conditions as follows:
1. Low oil indicator (Fig A)
The low oil indicator light (4) is a red
LED and will illuminate when the oil
level of the generator is too low. The
generator will stop operating within
10 seconds if the red light comes on.
The red LED will illuminate when the
generator is being attempted to start
if the oil is low, i.e. when the cord is being pulled, the red LED will glow if
there is insufficient oil. In this condition, the generator will not start. In this
condition you need to add oil for the generator to operate.
2. Load Status indicator (Fig B)
The red load status indicator light
(5) advises the operator that a fault
has been detected and the power
supply to the control panel has been
interrupted. When the red load status
indicator is operating red, there is NO
240Va.c. available to the control panel.
NOTE: The engine must be stopped and the issue resolved before the
power supply will be restored.