Cooling Capacity - With Air Handler Coils - York H*RE024 Technical Manual

Split-system air conditioners 14 seer 2 thru 5 nominal tons
Table of Contents

Advertisement

COOLING CAPACITY - With Air Handler Coils

UNIT MODEL
MODEL
H1RE024S06
N1AHB0806
H1RE030S06
N1AHB1206
N1AHB1206
N1AHB1206
H1RE036S06
N1AHD1406
N1AHD1406
N1AHC1606
H2RE042S06
N1AHC1606
N1AHD1406
N1AHD2006
H2RE048S06
N1AHD2006
N1AHD2006
H2RE060S06
N1AHD2006
N1VSB12
H1RE024S06
N1VSB12
N1VSB12
H1RE030S06
N1VSB12
N1VSB12
H1RE036S06
N1VSC16
N1VSC16
H2RE042S06
N1VSC16
N1VSD20
N1VSC16
H2RE048S06
N1VSD20
N1VSD20
H2RE060S06
N1VSD20
F2RP/FP036
H1RE024S06
F2FP040
F2RP/FP036
H1RE030S06
F2FP045
F2RP/FP036
H1RE036S06
F2RP/FP042
F2FP045
F2FP045
H2RE042S06
F2FP048
F2FP060
H2RE048S06
F2FV060
F2FP060
H2RE060S06
F2FV060
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU's at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable
Unitary Products Group
AIR HANDLER
2
ELECTRIC
W
HEAT KW
1 PH 14 SEER AC WITH N-AH / G2FD
2,5,8,10
17
5,8,10,15,19
17
5,8,10,15,19
17
5,8,10,15,19
17
5,8,10,15
24
5,8,10,15
24
5,8,10,15,20
21
5,8,10,15,20
21
5,8,10,15
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
1 PH 14 SEER AC / N1VS - VARIABLE SPEED
10,15,18
17
10,15,18
17
10,15,18
17
10,15,18
17
10,15,18
17
10,15,18
21
10,15,18
21
10,15,18
21
10,15,18,30
24
10,15,18
21
10,15,18,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
1 PH 14 SEER AC / F2RP / RC / FP / FC / FV
5,8,10,15,19
21
5,8,10,15
21
5,8,10,15,19
21
5,8,10,15
24
5,8,10,15,19
21
5,8,10,15
21
5,8,10,15
24
5,8,10,15
24
5,8,10,15,20,25
24
5,8,10,15,20,25
24
8,10,15,20,25
24
10,15,20,25
24
10,15,20,25
24
1
COIL
NET MBH
RATED
MODEL
CFM
TOTAL SENS.
G2FD036S17
800
25.2
G2FD036S17
1000
28.8
G2FD036S17
1200
34.0
G2FD046S17
1200
35.0
G2FD048S24
1200
35.4
G2FD060S24
1200
36.0
G2FD042S21
1400
39.0
G2FD048S21
1400
39.5
G2FD060S24
1400
40.5
G2FD060S24
1600
46.5
G2FD061H24
1600
47.0
G2FD060S24
1900
53.5
G2FD061H24
2050
54.5
G2FD036S17
870
25.6
G2FD046S17
870
26.2
G2FD036S17
1000
29.4
G2FD046S17
1070
30.0
G2FD046S17
1250
35.2
G2FD048S21
1285
36.0
G2FD048S21
1420
40.5
G2FD048S21
1420
40.5
G2FD060S24
1420
41.5
G2FD048S21
1590
46.0
G2FD060S24
1600
47.0
G2FD060S24
1780
53.5
G2FD061H24
1780
54.5
4,5
-
800
25.0
-
800
25.4
-
1000
29.8
-
1000
30.6
-
1200
34.4
-
1200
34.4
-
1200
36.0
-
1400
40.5
-
1400
39.5
-
1600
46.0
-
1625
47.5
--
1900
53.0
--
1900
53.5
.
models. All ratings remain the same.
036-21315-001 Rev. A (0502)
COOLING
SEER
SEER
3
W/O TXV
+ TXV
18.1
-
14.00
20.7
-
13.10
24.5
-
13.35
25.6
-
14.00
25.7
-
14.00
26.1
-
14.20
28.2
-
13.25
28.9
-
13.50
29.6
-
14.00
33.9
-
13.85
34.3
-
14.00
37.1
-
13.50
39.1
-
13.50
18.1
-
15.00
18.9
-
15.50
20.7
-
14.50
21.6
-
15.35
25.6
-
14.00
25.7
-
15.00
28.9
-
14.50
28.9
-
14.50
29.6
-
15.50
33.2
-
14.30
33.9
-
14.65
36.3
-
13.75
37.0
-
14.00
18.0
-
13.80
17.4
-
14.00
21.5
-
13.85
21.5
-
14.00
24.8
-
13.50
24.8
-
13.30
25.5
-
14.00
29.8
-
14.00
28.9
-
13.25
33.4
-
13.00
34.9
-
15.50
36.7
-
13.00
36.3
-
13.75
EER
12.35
11.80
11.80
12.20
12.50
12.80
11.35
11.60
12.00
11.80
11.90
12.00
12.10
13.85
14.15
12.95
13.60
12.40
13.60
12.50
12.50
13.20
12.20
12.40
12.35
12.60
12.30
12.75
12.40
12.70
12.10
11.90
12.65
12.00
11.30
11.25
13.20
11.60
12.35
3